Medical device makerLabelled by claude-haiku-5.5 from the firm's FDA names. It is not an FDA field. in United StatesLabelled by claude-haiku-5.5 from the firm's FDA names. It is not an FDA field., part of EnvistaLabelled by claude-sonnet-5.5 from the firm's FDA names. It is not an FDA field.. FDA records under 3 spellings of its name, each linked to the record.
As of Nov 22, 2026, FDA's public records list Implant Direct Sybron Manufacturing with 33 device recalls and 17 510(k) clearances. The most recent is a device recall dated May 1, 2025: The Drill Stop Kit is the version of the Mini Sterilizable Tray that is used to store, s….
Drug approvals, 510(k) clearances, recalls and letters, 2017 to 2026 to date
A hatched bar is a year that is not over, so its count covers only part of the year.
| May 1, 2025 | The Drill Stop Kit is the version of the Mini Sterilizable Tray that is used to store, sterilize, verify Drill Stop length, and facilitate…Class II · The Drill stop kit contains incorrect components. | Device recall |
| Aug 16, 2023 | Guided Surgery KitK231087 · DZI | 510(k) clearance |
| Jun 20, 2023 | SMARTbase Abutment SystemK223535 · NHA | 510(k) clearance |
| May 2, 2023 | Legacy smartbase, ne 3.0D 1MML, ref: 8730-81NE; legacy smartbase, ne 3.0D 2MML, ref 8730-82NE; legacy smartbase narrow ne 3.5D, ref…Class II · Non-engaging abutments were distributed without FDA clearance; the performance characteristics have not yet been… | Device recall |
| Feb 2, 2023 | Implant Direct Dental Implant Systems Portfolio - MR ConditionalK222211 · DZE | 510(k) clearance |
| Sep 23, 2021 | ImplantDirect, REF 834713, Legacy 2 Implant 4.7mmD x 13mmL, 4.5mmD Platform,Class II · Packaged dental implant contains a different size then the size declared on the labeling. | Device recall |
| Sep 23, 2021 | ImplantDirect, REF 834711, Legacy 2 Implant 4.7mmD x 11.5mmL, 4.5mmD Platform,Class II · Packaged dental implant contains a different size then the size declared on the labeling. | Device recall |
| Jan 28, 2021 | Standard Sterilizable TrayK202524 · KCT | 510(k) clearance |
| Jan 22, 2021 | Simply Iconic ImplantsK201553 · DZE | 510(k) clearance |
| Aug 6, 2020 | Mini Sterilizable TrayK200858 · KCT | 510(k) clearance |
| Jun 30, 2020 | Surgical DrillsK200265 · DZI | 510(k) clearance |
| Jun 25, 2020 | Legacy2, Legacy3, Legacy4, simplyLegacy2, simplyLegacy3 dental implants and 1 moreK192221 · DZE | 510(k) clearance |
| Oct 11, 2019 | Implant Direct, CE 0086, REF: 855710, Legacy 3 Impant, Surface: SBM, Qty:1, Size:5.7mmD x 10mmL, 5.7mmD Platform, RxOnly, Sterile R,Class II · Through a customer complaint and and internal investigation it was determined that some implant packages contain the… | Device recall |
| Oct 7, 2019 | Legacy 3 Implant, Size: 4.2mmD x 13mmL, 3.5mmD Platform, REF: 864213Class II · Some dental implant packages contain incorrect implants, which could lead to surgery rescheduling. | Device recall |
| Jan 9, 2019 | SwishPlus Implant 5.7mmD x 8mmL, SBM 6.5mmD Platform, Part Number 925708Class II · Due to a complaint received and internal investigation it was determined that implant vials were distributed with… | Device recall |
Spellings are joined only when they reduce to the same name, or a reviewed source names the same company. Sharing an FDA establishment number (FEI) is not enough: contract sites make products for many firms. Facts marked AI were labelled by a language model from the firm's FDA names; everything else comes from FDA or Wikidata.