FDAのMAUDEデータベース検索
医療機器が人に危害を及ぼしたり、故障したりした可能性がある場合にFDAへ提出される報告です。誰でも報告できるため、注意すべき兆候ではあっても、機器が原因だった証拠ではありません。
MAUDE(Manufacturer and User Facility Device Experience)はFDAのデータベースです。医療機器との関連が疑われる死亡、重篤な傷害、不具合の報告を収録しています。openFDA版は、機器、製造業者、製品コード、事象の種類、日付、報告番号で検索できます。報告は確定した所見ではなく、報告件数は発生率ではありません。
- MAUDEの報告件数: 26,849,547, 2026年11月18日時点
- 死亡報告: 232,397
- 傷害報告: 9,656,791
- 不具合報告: 16,796,984
年別の受領報告件数
FDAの受領日で集計したMAUDE報告
- 通年
- 2026年の年初から2026年10月30日まで
| 機器と記述 | 報告 | 製造業者 | 問題 | 事象 | |
|---|---|---|---|---|---|
| 2026年10月30日 | da Vinci XiIt was reported that prior to the start of a da Vinci-assisted Radical Transvesical Prostatectomy surgical procedure, the customer observed the left arm on the Surgeon Side Console (SSC) was drifting. It was noted that once the surgeon went into the viewer with their head, the arm started to drift…記述の全文Description of Event or Problem It was reported that prior to the start of a da Vinci-assisted Radical Transvesical Prostatectomy surgical procedure, the customer observed the left arm on the Surgeon Side Console (SSC) was drifting. It was noted that once the surgeon went into the viewer with their head, the arm started to drift or move by itself. The customer informed the surgeon finds it not safe anymore to keep using the system as is. The procedure was completed with no report of patient injury. Additional Manufacturer Narrative An Intuitive Surgical, Inc. (ISI) Field Service Engineer (FSE) was dispatched to the customer site to further investigate the reported event. Based on the field evaluation, this reported event was confirmed. The FSE recalibrated the Master Tool Manipulator (MTM). The system was tested and verified as ready for use. | 2955842-2026-43622 | Intuitive Surgical, Inc (英語)製品コード NAY (英語) · モデル 380723-06 · Manufacturer | 機器の問題: Unintended System Motion患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | FreeStyle Libre 3 PlusA customer reported a missing signal loss alarm issue with the Abbott Diabetes Care (ADC) device. There was no indication that the customer experienced an adverse event or required intervention as a result of the reported issue. There was no report of death, serious injury, or mistreatment…記述の全文Description of Event or Problem A customer reported a missing signal loss alarm issue with the Abbott Diabetes Care (ADC) device. There was no indication that the customer experienced an adverse event or required intervention as a result of the reported issue. There was no report of death, serious injury, or mistreatment associated with this event. Additional Manufacturer Narrative The product has been requested back for investigation and the customer agreed to return the device. A follow-up report will be submitted upon completion of investigation activities or if additional information is obtained. \\All pertinent information available to Abbott Diabetes Care has been submitted. | 2954323-2026-448743 | Abbott Diabetes Care Inc (英語)製品コード QBJ (英語) · モデル 78768-01 · Manufacturer | 機器の問題: Device Alarm System患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | FreeStyle Libre 2 PlusA high readings issue with the Abbott Diabetes Care (ADC) device was reported. The customer received an unspecified high scan on the ADC device compared to unknown readings obtained on an unknown device. It is unknown whether the customer noted a trend arrow on the device. The customer experienced…記述の全文Description of Event or Problem A high readings issue with the Abbott Diabetes Care (ADC) device was reported. The customer received an unspecified high scan on the ADC device compared to unknown readings obtained on an unknown device. It is unknown whether the customer noted a trend arrow on the device. The customer experienced unknown symptoms and took insulin (type/dose unspecified) which were prescribed earlier. The patient was taken to the emergency room (ER) after getting a reading of 400 mg/dL from an HCP meter. Customer was administered with unknown treatment by healthcare personal (HCP). There was no report of death or permanent impairment associated with this event. Additional Manufacturer Narrative The product has been requested back for investigation and the customer agreed to return the device. A follow-up report will be submitted upon completion of investigation activities or if additional information is obtained. \\All pertinent information available to Abbott Diabetes Care has been submitted. | 2954323-2026-448742 | Abbott Diabetes Care Inc (英語)製品コード QBJ (英語) · モデル 78747-01 · Manufacturer | 機器の問題: High Readings患者に生じた問題: Hyperglycemia転帰: Required intervention | 傷害 |
| 2026年10月30日 | LifeVest WCD 5100 SystemA US distributor contacted ZOLL to report that a patient developed a bruise under the LifeVest equipment. Patient described the area as a tiny bruise on the side of the body. There was no alleged device malfunction contributing to the bruise. The patient’s nurse was present, but there is no…記述の全文Description of Event or Problem A US distributor contacted ZOLL to report that a patient developed a bruise under the LifeVest equipment. Patient described the area as a tiny bruise on the side of the body. There was no alleged device malfunction contributing to the bruise. The patient’s nurse was present, but there is no indication of medical intervention for the bruise. Reporting out of an abundance of caution. Follow up indicated that the bruise improved. Additional Manufacturer Narrative Not applicable | 3008642652-2026-10451 | ZOLL Manufacturing Corporation (英語)製品コード MVK (英語) · モデル LifeVest WCD 5100 System · Manufacturer | 機器の問題: Patient Device Interaction Problem患者に生じた問題: Skin Inflammation/ Irritation | 傷害 |
| 2026年10月30日 | CADD-Solis VIP Ambulatory Infusion PumpIt was found during the investigation of the returned pump that the detached Downstream Occlusion (DSO) seal was identified through visual inspection. There was no patient involvement associated with this event, and no patient harm was reported.記述の全文Description of Event or Problem It was found during the investigation of the returned pump that the detached Downstream Occlusion (DSO) seal was identified through visual inspection. There was no patient involvement associated with this event, and no patient harm was reported. Additional Manufacturer Narrative The suspected device was returned for evaluation. The review of event log performed and found nothing related to complaint. A review of the available service history identified no previous related repairs within the last 12 months. The visual inspection and functional testing were performed and detached Downstream occlusion (DSO) seal was found. The customer complaint was confirmed as the investigation identified the detached DSO seal through visual inspection. The probable cause of the reported issue could not be determined. The device passed all functional testing after repair. | 3012307300-2026-09773 | ICU Medical, Inc. (英語)製品コード FRN (英語) · Manufacturer | 機器の問題: Detachment of Device or Device Component患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | Omnipod 5 Automated Insulin Delivery SystemIt was reported by the legal guardian that the patient's blood glucose level rose to 300 mg/dL while wearing the Pod between 5 and 24 hours. When removed from the infusion site (arm), the Pod's cannula was found blocked and the infusion site was bleeding. As treatment, a new Pod was applied.記述の全文Description of Event or Problem It was reported by the legal guardian that the patient's blood glucose level rose to 300 mg/dL while wearing the Pod between 5 and 24 hours. When removed from the infusion site (arm), the Pod's cannula was found blocked and the infusion site was bleeding. As treatment, a new Pod was applied. Additional Manufacturer Narrative The device has not been returned/received to date. If the device is received, a supplemental report will be submitted with the investigation results. We are unable to determine if any product condition could have contributed to the reported event. Lot Release records were reviewed, and the product lot met all acceptance criteria. \\Locked Down Smartphone: LOCKDOWN\Omnipod Software App Version: 4.0.3\Operating System: N5004L-AM-Q-MV01602-06-01.06\Hardware: N5004L\CGM Sensor Type: Data not available\Please note, the device identifiers are captured as reported by the complainant and may not align with the device configuration reported in this section as this data is pulled from our Cloud based on the reported date of event. | 3014585508-2026-79826 | Insulet Corporation (英語)製品コード QFG (英語) · モデル PT-001446 · Manufacturer | 機器の問題: Obstruction of Flow; Insufficient Device Problem Information患者に生じた問題: Hemorrhage/Blood Loss/Bleeding; Hyperglycemia | 不具合 |
| 2026年10月30日 | EVIS EXERA III COLONOVIDEOSCOPEThe customer returned the colonovideoscope for a separate issue. During initial evaluation of the returned device, it was found that horizontal line in image. There was no patient involvement reported.記述の全文Description of Event or Problem The customer returned the colonovideoscope for a separate issue. During initial evaluation of the returned device, it was found that horizontal line in image. There was no patient involvement reported. Additional Manufacturer Narrative Based on the final investigation of the device horizontal line in image. The initial evaluation finding was confirmed.\\A root cause could not be identified. Based on the results of the investigation, the most probable cause of horizontal line in image cause due to cause traced to component failure.\\Date of event is unknown. Additional information will be provided if available.\\Olympus will continue to monitor the field performance of this device. \\Should any additional relevant information become available, a supplemental report will be submitted. | 9610595-2026-88175 | Aizu Olympus Co., Ltd. (英語)製品コード FDF (英語) · モデル PCF-H190I · Manufacturer | 機器の問題: Poor Quality Image患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | FOGARTY SAFEJAW | 2015691-2026-19852 | Edwards Lifesciences PR (英語)製品コード DXC (英語) · モデル DSAFE86 · Manufacturer | 機器の問題: Contamination患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | Gallant HFIt was reported during remote follow up that the Post-Paced T-wave Oversensing (PPTWOS). The product will continue to be monitored. There were no patient consequences.記述の全文Description of Event or Problem It was reported during remote follow up that the Post-Paced T-wave Oversensing (PPTWOS). The product will continue to be monitored. There were no patient consequences. | 2017865-2026-22823 | Abbott Medical (CRM-Sylmar) (英語)製品コード NIK (英語) · モデル CDHFA500Q · Manufacturer | 機器の問題: Over-Sensing患者に生じた問題: No Clinical Signs, Symptoms or Conditions | 不具合 |
| 2026年10月30日 | t:slim X2 Insulin Pump with Control-IQ+ TechnologyIt was reported that pump issued occlusion alarms resulting in the customer going to the emergency room the next date, (b)(6) 2026. The customer was admitted to the hospital's intensive care unit with a blood glucose level of 426 mg/dL, a healthcare provider identified ketone level as dangerous or…記述の全文Description of Event or Problem It was reported that pump issued occlusion alarms resulting in the customer going to the emergency room the next date, (b)(6) 2026. The customer was admitted to the hospital's intensive care unit with a blood glucose level of 426 mg/dL, a healthcare provider identified ketone level as dangerous or life threatening. Customer was treated with intravenous fluids of saline and insulin which resolved the issue. The customer was released the same day with issue resolved and no permanent damage. Customer reported using the same cartridge for more than 48 hours and received education from Technical Support to change cartridge every 48 hours with Humalog brand insulin, after which case was closed. Additional Manufacturer Narrative In use at the time of the event:\\CGM model: Unknown.\\Mobile OS: iOS / iOS_iPhone XS / Unknown / iOS_17.3.1. | 3013756811-2026-197917 | Tandem Diabetes Care (英語)製品コード QFG (英語) · モデル 1000354 · Manufacturer | 機器の問題: Obstruction of Flow患者に生じた問題: Hyperglycemia; Elevated Ketones/ Diabetic Ketoacidosis転帰: Hospitalization; Required intervention | 傷害 |
集計対象は報告であり、事象ではありません。1件の集約報告に複数の事象が含まれることも、同じ事象が複数回報告されることもあります。件数は事象の発生頻度を示しません。openFDAはデータを未検証としています。 FDA MAUDE(openFDA経由) · 更新日:2026年11月18日
このデータについて
収録データの内訳
2026年10月30日までのデータです。集計対象は報告であり、事象ではありません。1件の集約報告に複数の事象が含まれることも、同じ事象が複数回報告されることもあります。データはopenFDAの医療機器事象エンドポイントから取得しており、事象の発生頻度を示しません。
- openFDA版MAUDEの報告件数
- 26,849,547
- FDAが受領した最新報告
- 2026年10月30日
- openFDAの最終更新
- 2026年11月18日
事象の種類別の報告件数
年別の受領報告件数
- 2026 (2026年10月30日まで)
- 3,216,386
- 2025
- 2,888,003
- 2024
- 2,627,151
- 2023
- 2,339,806
- 2022
- 2,945,385
- 2021
- 2,028,310
- 2020
- 1,564,999
- 2019
- 1,328,955
- 2018
- 1,048,082
- 2017
- 936,902
- 2016
- 867,447
出典:FDAのMAUDEデータベースの報告を再掲載するopenFDAの医療機器事象API。openFDAはデータを未検証としています。
MAUDEとは
MAUDEはManufacturer and User Facility Device Experienceの略です。FDAが受領した医療機器報告(Medical Device Reports、MDR)を収録しています。対象は、機器との関連が疑われる死亡、重篤な傷害、不具合です。FDAはMAUDEを受動的な監視システムと位置づけています。提出された報告を記録し、事象を能動的に探す仕組みではありません。
FDAのMAUDE検索ページには過去10年分の報告があり、前月末までの受領分を毎月反映します。以前の報告は、FDAが公開するMDRデータファイルからダウンロードできます。FDAのMDRページによると、年間200万件を超える報告が寄せられます。
このツールはopenFDA版のMAUDEを参照します。openFDAによると、収録期間はおおむね1992年から現在までで、毎週更新されます。各結果からFDAのMAUDEサイトにある同じ報告を開き、原典を確認できます。
このツールでMAUDEを検索する方法
1つ以上の欄に入力します。条件を追加すると結果が絞られます。初期表示はFDAの受領日が新しい順で、1ページに10件表示します。日付列を選ぶと並び順が逆になります。ページ送りの上限に達したら、期間を短くするか、条件を追加してください。検索結果のURLをコピーすると条件を共有できます。
- 機器名または販売名。 販売名、一般名称、FDAの標準機器名を対象にフレーズで照合します。「insulin pump」で検索すると、数十の販売名の報告が見つかります。
- 製造業者。 報告のセクションDに記載された対象機器の製造業者を照合します。報告によって表記が異なるため、「Medtronic」などの短い名称で検索してください。
- 製品コード。 FDAが機器の種類に付ける3文字のコードです。510(k)検索と同じコードで、該当する報告に絞れます。
- 事象の種類。 死亡(Death)、傷害(Injury)、不具合(Malfunction)、その他(Other)です。
- 機器または患者の問題。 バッテリー故障や感染など、報告でコード化された問題を照合します。
- 記述に含まれる語句。 事象の説明と製造業者の自由記述を検索します。
- FDA受領日。 対象はFDAが報告を受領した日の範囲で、事象が起きた日ではありません。
- 報告番号またはMDR報告キー。 番号が引用されている場合に、特定の報告を探せます。
次の例から検索を始められます。
MAUDEに報告する人と組織
報告者は2つのグループに分かれます。製造業者、輸入業者、医療機器使用施設には報告義務があります。医療従事者、患者、介護者、消費者は、FDAのMedWatchを通じてForm FDA 3500で任意に報告します。
医療機器使用施設には、病院、外来手術施設、介護施設、外来診断施設、外来治療施設が含まれます。医師の診療所は含まれません。各結果の報告元を見ると、提出したグループが分かります。openFDAの値は「manufacturer report」「distributor report」「user facility report」「voluntary report」です。
openFDA版では、製造業者の報告が大半を占めます。規則上、製造業者の報告義務は不具合も含めて最も広く、使用施設には不具合を報告する義務がないためです。
義務報告と任意報告
医療機器報告規則の21 CFR Part 803は、誰が何をいつまでに報告するかを定めています。FDAは義務報告の案内ページで要件をまとめています。
| 報告者 | 報告内容 | 報告先 | 期限 |
|---|---|---|---|
| 製造業者 | 死亡、重篤な傷害、再発した場合に死亡や重篤な傷害の原因となるか寄与する可能性が高い不具合 | FDA | 知った日から30暦日以内 |
| 製造業者 | FDAが指定した事象、または重大な危害の不合理なリスクを防ぐために是正措置を要する事象 | FDA | 知った日から5営業日以内 |
| 輸入業者 | 死亡と重篤な傷害 | FDAと製造業者 | 知った日から30暦日以内 |
| 輸入業者 | 再発すると死亡や重篤な傷害を引き起こす、または一因となる可能性が高い不具合 | 製造業者のみ | 知った日から30暦日以内 |
| 使用施設 | 機器に関連する死亡 | FDAと製造業者 | 知った日から10営業日以内 |
| 使用施設 | 機器に関連する重篤な傷害 | 製造業者。不明の場合はFDA | 知った日から10営業日以内 |
| 使用施設 | 死亡および重篤な傷害の報告の年次集計(Form FDA 3419) | FDA | 前年分を1月1日までに提出 |
それ以外は任意です。使用施設は不具合に気づいたとき、医療従事者や患者は製品の問題に気づいたとき、MedWatchで報告できます。任意報告には義務報告の基準が適用されないため、製造業者の30日報告とは性質の異なる証拠です。
報告番号から報告元が分かります。義務報告の番号には通常、提出者の登録番号、4桁の年、連番が含まれます。例は3004593495-2020-00473です。任意報告の番号はMWで始まります。
MAUDE報告の内容
FDAは各項目の説明を公開しています。よく使う項目と、そのFDAの定義を以下に示します。
| 項目 | 内容 |
|---|---|
| 販売名 | 対象機器の表示やカタログに記載された販売名または固有の商品名。 |
| 機器の一般名称 | 対象機器の一般名または説明的な名称。 |
| 製造業者(セクションD) | 対象機器の製造業者の名称と住所。 |
| 製品コード | FDAが機器の種類に付けたコード。FDAのProduct Classification Databaseで確認できます。 |
| モデル番号 | 機器のラベルや包装に印刷された番号。 |
| 報告番号 | 提出者が付けた報告の識別番号。追加報告で変わりません。 |
| MDR報告キー | MAUDEが付けた一意のキー。追加報告で変わりません。 |
| 事象発生日 | 有害事象が始まった実際の日付、または最も確からしい推定日。 |
| 受領日 | FDAが初回報告を受領した日。追加報告を受けても変わりません。 |
| 報告対象事象の種類 | 死亡、重篤な傷害、不具合。openFDAでは重篤な傷害をInjuryと表示します。 |
| 医療機器の問題コード | 機器の故障や問題を表すために提出者が選んだコード。 |
| 健康への影響の臨床コード | 患者に何が起きたかを表すために提出者が選んだコード。 |
| 事象または問題の説明 | 報告内容を説明する自由記述。 |
| 製造業者の追加記述 | 製造業者が提出した報告に含まれる、製造業者自身の評価の記述。 |
| PMAまたは510(k)番号 | 対象機器について承認されたPMA、クリアランスを受けた510(k)、またはその他の販売申請。 |
| 報告の種類 | 初回または追加報告。追加報告を受領するごとに1件を記録します。 |
| 集約した事象の数 | 1件の集約報告に含まれる事象の数。 |
| UDI-DIおよびUDI-Public | ラベル上の機器識別子。シリアル番号などの非開示項目は除きます。 |
1件の報告に複数の機器が記載されることがあります。このツールは最初の機器を表示し、ほかの機器が何件記載されているかを示します。
事象と報告の種類
事象の種類
用語は規則で定義されています。死亡とは、報告者が機器によって生じたか、機器が一因となった可能性があると考える死亡です。重篤な傷害とは、生命を脅かす傷害や疾病、身体機能に永続的な障害または身体構造に永続的な損傷をもたらすもの、またはそうした結果を防ぐために医学的もしくは外科的介入を要するものです。不具合とは、機器が性能仕様を満たさないか、意図どおりに機能しないことです。少数の報告にはOther、空欄、またはNo answer providedが記録されています。
FDAは死亡の分類について、機器が要因となったか、その可能性があると報告者が考える場合に限ると明示しています。記述に「death」という語があるだけで、死亡報告になるわけではありません。
報告の種類
- 初回報告と追加報告。 追加報告を受けると、MAUDEは最新情報を表示し、一部の項目に情報を追加します。確認できるのは報告の現時点の内容で、変更履歴ではありません。
- 集約報告。 1件の報告で複数の事象を扱えます。FDAのVoluntary Malfunction Summary Reporting Programでは、対象の製造業者が不具合を集約して報告できます。集約した事象の数は専用欄に記載されます。報告件数と事象件数は別です。
- 免除等。 21 CFR 803.19に基づく免除、特例、代替手続で提出した報告には免除番号が付きます。RWDYYXXXXX形式なら、製造業者が登録データ、診療記録、請求データなどのリアルワールドデータから情報を得たことを示します。
- 転送通知。 製造業者または輸入業者が、自社で製造も輸入もしていない機器の有害事象情報を受け取った場合、21 CFR 803.22(b)(2)に基づきFDAに転送する必要があります。FDAはその旨を記述に追記します。
FDAのMAUDE検索には、古い報告のうち2系統が含まれません。1999年から2019年4月までのAlternative Summary Reporting Programと、1984年から1996年までの旧Device Experience Networkです。どちらもMDRデータファイルのページに掲載されています。
MAUDEから分からないこと
FDAは、MDRデータを有害事象の発生率の評価、その経時変化の評価、機器間の発生率の比較に使うことは想定していないと明示しています。この限界を踏まえて結果を読んでください。
- 報告は確定した所見ではありません。 21 CFR 803.16では、報告は提出者やFDAが機器を事象の原因や一因と結論づけたことを必ずしも意味しません。報告者が因果関係を否定する場合もあります。
- 分母がありません。 MAUDEには使用中の機器の台数がありません。数百万件の処置で使われる機器は、数千件で使われる機器よりも、安全性が高くても報告件数が多くなります。
- 報告漏れがあります。 FDAは、報告漏れ、不正確な記載、検証の不足、機器の使用頻度の情報不足を、MAUDEだけでは事象の発生率や原因を判断できない理由に挙げています。
- 直近数か月のデータは最も不完全です。 製造業者の期限は認知から30日で、FDAは毎月公開します。最近の事象の報告はその後も数週間にわたり届きます。
- 名称は標準化されていません。 同じ製造業者や販売名に複数の表記が使われることがあります。短い名称で検索し、結果を確認してください。
- 表記が不統一な項目があります。 openFDA版では同じ報告者区分にForeign、FOREIGN、FOREIGが混在します。患者の転帰には単語と1文字のコードが混在し、一部には1900年に受領したといった不自然な日付もあります。このツールは転帰の表示を整え、それ以外はFDAの公開内容のまま表示します。
- 非開示の記述があります。 FDAは営業秘密を(b)(4)に、個人情報や診療記録の情報を(b)(6)に置き換えます。記述から文が抜けたように見える箇所では、実際に削除されている場合があります。
- 報告は独立していません。 同じ事象を病院、製造業者、輸入業者がそれぞれFDAに報告することがあります。
FDAはMDRを市販後データの情報源の1つとしています。登録データ、臨床研究、回収情報は、MAUDEで得られない情報を補います。企業の市販後監視 (英語)では、これらすべてを活用することが推奨されます。
記述欄の読み方
記述欄には報告の具体的な内容があり、通常は短い英文が大文字で書かれています。次の順で確認してください。
- 事象の種類と記述を照合します。患者への危害がない不具合(Malfunction)は、傷害(Injury)とは異なるシグナルです。
- 誰の記述かを分けます。事象または問題の説明は報告者の記述です。製造業者の追加記述は製造業者の調査です。
- 評価内容を確認します。製造業者が機器を回収して試験したのか、報告者の説明だけで結論を出したのかを確かめます。機器を評価できたかどうかは報告に記載されています。
- 患者欄を読みます。患者に生じた問題と転帰から、何が起きたかが分かります。「No consequences or impact to patient」はよくある記載です。
- 非開示箇所や定型文を確認します。「今後情報が提供されれば追加報告を提出する」といった定型文には、新しい情報はありません。
- 報告の種類を確認します。追加報告で初回提出時の記述が変わった可能性があります。
短い例として、FDAが2020年4月27日に受領した報告3004593495-2020-00473を見てみましょう。製造業者が一時使用の体外式ペースメーカーについて提出した不具合(Malfunction)報告です。事象の説明は次のとおりです。
IT WAS REPORTED THE EXTERNAL PULSE GENERATOR (EPG), ATRIAL SENSE LIGHT EMITTING DIODE (LED ) WAS GREEN. THE EPG WAS RETURNED FOR ANALYSIS. NO PATIENT COMPLICATIONS HAVE BEEN REPORTED AS A RESULT OF THIS EVENT.
報告者によると、心房センシングの表示灯が緑色でした。機器を返送された製造業者は、不具合を確認し、シールの損傷と回路基板に誤った部品が付いていることを突き止めました。部品の交換後、機器は最終試験に合格しました。患者の問題は「No consequences or impact to patient」としてコード化されています。この報告では、不具合の内容、製造業者が確認したこと、危害の報告がなかったことが分かります。同じ誤った部品が付いた機器がほかに何台あるかは、MAUDEからは分かりません。
MAUDEと回収・510(k)クリアランスの関係
MAUDEは事象を記録します。回収は製品への措置です。510(k)は製品の米国市場投入を可能にしたクリアランスです。これらは一部の項目でつながり、個別のツールで調べられます。
- 510(k)クリアランス。 報告のPMA番号または510(k)番号は、対象機器の販売を認めた手続を示します。製品コードは類似機器をまとめるためのものです。510(k)検索でコードを検索すると、クリアランス、申請者、そのコードでクリアランスを受けた他の機器を確認できます。比較対照機器の候補を選ぶ際は、採用前に候補機器の製品コードにひもづくMAUDE報告を確認すると役立ちます。
- 回収。 報告に回収などの是正措置が記載される場合があります。ただし、ほとんどの報告は回収につながりません。特定の故障モードに関する回収は、回収検索 (英語)で調べられます。
- 機器の識別。 報告にUDIが記載される場合があります。手元に機器があれば、GUDID機器検索で販売名、モデル、製造業者を調べ、その情報をこのツールで検索してください。
品質不良への対応は、CAPA、Form 483、FDA警告書 (英語)の解説を参照してください。これらの文書が後に取り上げる問題は、MDRで初めて公に確認できることがよくあります。
MAUDEデータを入手する他の方法
- FDAのMAUDE検索。 公式の検索画面です。過去10年分を対象とし、FDAが公開するすべての項目を表示します。
- MDRデータファイル。 過去の報告をまとめたZIPファイルです。任意報告は1993年6月、使用施設の報告は1991年、販売業者の報告は1993年、製造業者の報告は1996年8月までさかのぼります。FDAは毎月更新します。
- openFDA API。 このツールが使う無料のAPIです。キーがない場合は、1 IPアドレスあたり1分間に240リクエスト、1日に1,000リクエストまでです。無料のキーを使うと1日あたり120,000リクエストまで利用できます。
機器の問題を自分で報告するには、MedWatchを利用してください。医療従事者、患者、介護者が提出できます。
よくある質問
- MAUDEデータベースとは何ですか?
- MAUDE(Manufacturer and User Facility Device Experience)はFDAのデータベースです。医療機器との関連が疑われる死亡、重篤な傷害、不具合に関する医療機器報告(MDR)を収録しています。製造業者、輸入業者、医療機器使用施設のほか、医療従事者や患者などが任意で提出した報告も含まれます。
- MAUDEのデータで機器を比較できますか?
- できません。FDAは、MDRデータを事象の発生率、その経時変化、機器間の発生率の差の評価に使うことを想定していません。受動的な報告制度なので使用中の機器の台数は分かりません。また、報告だけで機器が事象の原因だったとは証明できません。
- 誰がMAUDEに報告する義務を負いますか?
- 21 CFR Part 803に基づき、製造業者、輸入業者、医療機器使用施設は一定の事象を報告する義務があります。製造業者は死亡、重篤な傷害、一部の不具合を30暦日以内にFDAへ報告します。使用施設は死亡を10営業日以内にFDAと製造業者へ報告します。それ以外の人はMedWatchで任意に報告できます。
- 義務報告と任意報告はどう違いますか?
- 義務報告は、報告義務がある製造業者、輸入業者、使用施設が提出します。任意報告は医療従事者、患者、消費者がMedWatchのForm FDA 3500で提出します。任意報告の番号はMWで始まります。
- MAUDEは何年までさかのぼれますか?
- FDAのMAUDE検索は過去10年分を表示します。FDAのダウンロード用MDRデータファイルでは、使用施設の報告は1991年、製造業者の報告は1996年8月までさかのぼります。このツールが参照するopenFDA版は、おおむね1992年以降を収録します。
- MAUDEはどのくらいの頻度で更新されますか?
- FDAは前月末までに受領した報告をMAUDE検索に毎月反映します。openFDAによると、そのコピーは毎週更新されます。このページには最新報告の受領日とopenFDAの最終更新日を表示します。
- MAUDE報告の(b)(4)と(b)(6)は何を意味しますか?
- 米国のFreedom of Information Actに基づきFDAが非開示とした箇所を示します。(b)(4)は営業秘密や企業の機密情報を、(b)(6)は患者の生年月日などの個人情報や診療記録の情報を置き換えます。
- MAUDE報告があれば回収が行われたということですか?
- いいえ。報告は事象を記録するもので、回収は製品への別の措置です。報告に回収などの是正措置が記載される場合はありますが、ほとんどの報告は回収につながりません。
- このツールはFDAのMAUDEサイトを検索しますか?
- いいえ。ブラウザーから、同じ報告を収録するopenFDA版をその場で検索します。検索リクエストはArcaのopenFDAプロキシを経由します。各結果はFDAのMAUDEサイトにある同じ報告にリンクしています。
- 医療機器の問題はどう報告すればよいですか?
- FDAのMedWatchでオンラインまたはForm FDA 3500を使って報告してください。医療従事者、患者、介護者が報告できます。製造業者、輸入業者、使用施設はForm FDA 3500Aまたは同等の電子様式を使います。
有害事象を自社の記録と照合
ArcaはMAUDE報告をFDAの回収・クリアランス情報や自社の苦情・CAPA記録と照合し、各記述に出典の報告を示します。