On Jan 17, 2017, FDA's CDER sent Porton Biopharma Limited a warning letter citing aseptic processing, sterility assurance, environmental monitoring.
Letter date: Jan 17, 2017
Issued by: CDER
The Letter
As posted on FDA.gov ↗; cited 21 CFR sections link to their page.
• a restricted access barrier system (RABS) (b)(4) which had fallen off the enclosure system;
• a lack of environmental monitoring within the RABS;
• no use of sporicidal disinfectant on surfaces inside aseptic filling room (b)(4), although your environmental monitoring detected spore-forming organisms there; and
• a lack of traceability for media-filled vials.
• a floor exhaust vent, shown in smoke studies to remove air entering the filling room, blocked by ancillary equipment during media fill process simulations
• inadequate validation of the (b)(4) sterilization cycle used on equipment to be transferred into aseptic filling room (b)(4)