Warning Letter to Porton Biopharma Limited

Unspecified. See Porton Biopharma's company page or this site's inspections.

On Jan 17, 2017, FDA's CDER sent Porton Biopharma Limited a warning letter citing aseptic processing, sterility assurance, environmental monitoring.

  • Letter date: Jan 17, 2017
  • Issued by: CDER

The Letter

As posted on FDA.gov ↗; cited 21 CFR sections link to their page.

• a restricted access barrier system (RABS) (b)(4) which had fallen off the enclosure system;

• a lack of environmental monitoring within the RABS;

• no use of sporicidal disinfectant on surfaces inside aseptic filling room (b)(4), although your environmental monitoring detected spore-forming organisms there; and

• a lack of traceability for media-filled vials.

• a floor exhaust vent, shown in smoke studies to remove air entering the filling room, blocked by ancillary equipment during media fill process simulations

• inadequate validation of the (b)(4) sterilization cycle used on equipment to be transferred into aseptic filling room (b)(4)

Recent Letters Citing Aseptic processing

See them all