Warning Letter to Lernapharm (Loris) Inc.

Unspecified. See Lernapharm (Loris)'s company page or this site's inspections.

On Sep 4, 2018, FDA's CDER sent Lernapharm (Loris) Inc. a warning letter citing aseptic processing, sterility assurance, process validation.

  • Letter date: Sep 4, 2018
  • Issued by: CDER
  • Closeout: —

The Letter

As posted on FDA.gov ↗; cited 21 CFR sections link to their page.

• other potential contributors to the pinhole problem, such as packaging material integrity prior to production;

• risks that the leaking packages pose to patients and product quality, including lack of sterility;

• effectiveness of your corrective actions and preventive actions (CAPA); and

• full evaluation of scope and magnitude to determine impact of the manufacturing problems on other batches of (b)(4) and additional products you manufacture.

• Your comprehensive investigations into the additional 18 batches potentially affected by debris on the sealing (b)(4), including your CAPA and a plan to ensure its effectiveness. If these investigations reveal any substandard quality drug products, provide actions that you will take such as notifying customers and product recalls.

• An update on your root-cause evaluations and related CAPA for all complaints you received relating to non-integral containers (e.g, leaking containers, dried contents), with special emphasis on further mitigation of human factors associated with the manufacturing process, in-process checks, and final inspection.

• An improved process for risk assessment.

• Your updated assessment of patient hazards associated with loss of package integrity.

• A comprehensive, independent assessment of your overall system for investigations of deviations, atypical events, complaints, out-of-specification results, and failures. Your CAPA should include but not be limited to improvements in investigation competencies, root-cause analysis, remediation, written procedures, and quality unit oversight. Also, include your process for evaluating CAPA effectiveness.

• a full summary of stability data results for all batches tested, with each time interval, attributes tested, the testing methods used, and the written stability protocol that was followed. Include testing of all microbiological and chemical attributes, and any updated test data to determine whether the integrity of your container-closure systems (and products are sterile, as applicable) is maintained throughout the entire shelf life.

• a comprehensive assessment and CAPA to ensure the adequacy of your stability program. Your CAPA should include, but should not be limited to a remediated standard operating procedure (SOP) describing your stability program; stability-indicating methods; stability studies to support each drug product in its container-closure system before distribution is permitted; an ongoing program in which representative batches of each product are added each year to the program to determine if the shelf-life claim remains valid; and specific attributes to be tested at each station.

• a protocol to review your (b)(4) filling and sealing zone, and support room environments, to determine whether they meet appropriate air classification standards, and any associated plans for facility upgrades.

• a comprehensive identification of all contamination hazards in your manufacturing operations and an independent risk assessment that includes, among other things, your manufacturing processes, equipment, and facilities to ensure their suitability for sterile production; and

• a detailed CAPA plan that describes all actions to be taken relating to facilities, equipment, manufacturing methods, controls, people, and raw materials to assure sterility.

• frequency, location, and duration of sampling; sample size; and specific sampling equipment and techniques;

• action and alert limits for each location, and a description of its function and ISO classification;

• instructions regarding investigations of out-of-limit (OOL) environmental monitoring results; and

• identification of microorganisms detected in environmental monitoring samples. For example, all microorganisms recovered in the filling room should be routinely identified.

• A list of all lots of sterile (b)(4) produced by your firm since January 2015 and all bioburden tests performed. Annotate which lots were tested for bioburden and timing of each sample ((b)(4) sterilization or earlier in the process). Include all microbial count test results and state whether microbial identification was performed. If so, provide the identity of each microbe.

• A list of all environmental monitoring tests done for sterile (b)(4) production since January 2015, date of the sample, location sampled, and the identity of all isolated organisms.

• Your bioburden monitoring and testing procedures.

• A list of any out-of-specification results from bioburden or environmental monitoring testing and all original results and related investigations (if any result was re-tested or invalidated).

Recent Letters Citing Aseptic processing

See them all

Record

Recipient
Mr. Razmik Margoosian
FDA site ID (FEI)
3004158845