On Aug 31, 2017, FDA's CDER sent Firson Co., Ltd. a warning letter citing aseptic processing, sterility assurance, capa.

  • Letter date: Aug 31, 2017
  • Issued by: CDER
  • Closeout: —

The Letter

As posted on FDA.gov ↗; cited 21 CFR sections link to their page.

• Provide a comprehensive review of your media fill program and corrective and preventive actions (CAPA) to ensure an appropriate simulation of the worst-case conditions of commercial manufacturing. Also detail how you examine units for presence of growth, and perform batch yield reconciliation.

• Describe whether your revised program requires (b)(4) to perform semi-annual media fills for each aseptic processing line.

• Provide a summary of all media fills performed since January 1, 2015, including processing line, date of media fill, number of units run, number examined, and number of potentially contaminated units found.

• Provide the complete sterility testing history for your (b)(4) products (include all sterility positives, irrespective of whether they were subsequently invalidated).

• Describe how you will adequately sterilize the drug formulation before aseptic filling. Provide your sterilization cycle parameters, validation protocols, validation reports, lethality of the process, and sterility assurance level.

• Describe whether your (b)(4) containers and closures are sterilized. Include sterilization methods, validation protocols, and validation reports for all (b)(4) containers and closures.

• Provide an action plan and timelines for implementing corrective actions, including notifying your customers and recalling any (b)(4) ointment drug products within expiry that were distributed to the U.S. and manufactured without adequate sterilization.

• Provide your environmental and personnel monitoring procedures. Justify monitoring locations, frequency, and action limits.

• Provide smoke studies under dynamic conditions that include a thorough and complete evaluation of aseptic interventions, and with unobstructed views. Also include your static smoke studies.

• Summarize the actions you have taken to comprehensively remediate your complaint investigation process. Include your revised investigation procedure(s) and the actions you are taking to ensure that your staff follows these procedures.

• Summarize your investigation findings using the revised procedures for each complaint related to drug quality received since January 2016. For each summary, include all test results, root causes, implicated batches distributed to the U.S. market, and CAPA.

• Provide an accelerated timeline to complete retroactive identification testsusing an appropriate identification method for all potentially compromised batches. Respond promptly with all results. If your data indicates that defective products are in the U.S. marketplace, commit to recall the products.

• Determine if all methods used to test your raw and in-process materials and finished drug products use USP-NF, or if not, employ an equivalent or better method. Provide a CAPA to address any inadequate methods that are identified.

Recent Letters Citing Aseptic processing

See them all

Record

Recipient
Mr. Kim Dong-Jin
FDA site ID (FEI)
3010219111

Tags are assigned by Arca from the letter's text. A closeout letter means FDA found the firm's corrections adequate; no closeout does not mean the issues are unresolved. FDA warning letters

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.