Arca
Skip to content
Tools
Tools

Warning Letter to Fancystage Unipessoal, LDA

Drugs. See Fancystage Unipessoal, LDA's company page or this site's inspections.

On Aug 3, 2023, FDA's CDER sent Fancystage Unipessoal, LDA a warning letter citing supplier controls, quality unit.

  • Letter date: Aug 3, 2023
  • Issued by: CDER
  • Closeout: —

The Letter

As posted on FDA.gov ↗; cited 21 CFR sections link to their page.

Warning Letter 320-23-25

August 3, 2023 Dear Ms. Teresa Neves:

Your facility is registered with the United States Food and Drug Administration (FDA) as a manufacturer of over-the-counter (OTC) drug products. FDA has reviewed the records you submitted in response to our March 17, 2023 request for records and other information pursuant to section 704(a)(4) of the Federal Food, Drug, and Cosmetic Act (FD&C Act) for your facility, Fancystage Unipessoal, LDA, FEI 3015282935, Rua Cumieira 31, Santiago Do Bougado Trofa, Porto, Portugal 4785-618.

This warning letter summarizes significant violations of Current Good Manufacturing Practice (CGMP) regulations for finished pharmaceuticals. See Title 21 Code of Federal Regulations, parts 210 and 211 (21 CFR, parts 210 and 211).

Because your methods, facilities, or controls for manufacturing, processing, packing, or holding of drugs as described in your response to our 704(a)(4) request do not conform to CGMP, your drug products are adulterated within the meaning of section 501(a)(2)(B) of the FD&C Act (21 U.S.C. 351(a)(2)(B)).

Following review of records and other information provided pursuant to section 704(a)(4) of the FD&C Act, significant violations were observed including, but not limited to, the following:

1. Your firm failed to conduct at least one test to verify the identity of each component of a drug product (21 CFR 211.84(d)(1)).

You manufacture several over-the-counter (OTC) drug products including (b)(4) and (b)(4) for children. Based on the records and information you provided, you did not demonstrate that you adequately tested each shipment of each lot of the incoming components at high-risk of (b)(4) or (b)(4) contamination. These include, but are not limited to, testing of (b)(4) and (b)(4) you used in manufacturing drug products to determine their appropriate identity. Identity testing for these and certain other high-risk drug components 1 include a limit test in the United States Pharmacopeia (USP) to ensure that the component meets the relevant safety limits for levels of (b)(4) or (b)(4). Because you did not perform identity testing on each shipment of each lot using the USP identification test that detects these hazardous impurities, you failed to assure the acceptability of these components for use in manufacture of your drug products.

The use of ingredients contaminated with (b)(4) or (b)(4) has resulted in various lethal poisoning incidents in humans worldwide. (b)(4).

In response to this letter, provide:

• A commitment to provide (b)(4) and (b)(4) test results, no later than 30 calendar days from the date of this letter, from testing retains for all lots of high-risk drug components used in the manufacture of drug products. Alternatively, if a retain of a component lot is unavailable, perform retain sample testing of all implicated finished drug product batches for the presence of (b)(4) and (b)(4).

• A full risk assessment for drug products that are within expiry which contain any ingredient at risk for (b)(4) or (b)(4) contamination. Take prompt and appropriate actions to determine the safety of all lots of the components and any related drug product that could contain (b)(4) or (b)(4), including customer notifications and product recalls for any contaminated lots. Identify additional appropriate corrective action and preventive action (CAPA) that secure supply chains in the future, including, but not limited to, ensuring that all incoming raw material lots are from fully qualified manufacturers and free from unsafe impurities. Detail these actions in your response to this letter.

• A description of how you will test each component lot for conformity with all appropriate specifications for identity, strength, quality, and purity. If you intend to accept any results from your supplier’s certificate of analysis (COA) instead of testing each component lot for strength, quality, and purity, specify how you will robustly establish the reliability of your supplier’s results through initial validation as well as periodic revalidation. In addition, include a commitment to always conduct at least one specific identity test for each incoming component lot. In the case of (b)(4), (b)(4), and certain additional high-risk components we note that this includes the performance of parts A, B, and C of the USP monograph.

• The chemical quality control specifications you use to test each incoming lot of high-risk drug components to determine acceptability for use in manufacturing.

• A comprehensive, independent review of your material system to determine whether all suppliers of components, containers, and closures, are each qualified and the materials are assigned appropriate expiration or retest dates. The review should also determine whether incoming material controls are adequate to prevent use of unsuitable components, containers, and closures.

• A summary of your program for qualifying and overseeing contract facilities that test the drug products you manufacture.

• A summary of results obtained from testing all components to evaluate the reliability of the COA from each component manufacturer. Include your standard operating procedure (SOP) that describes this COA validation program.

2. Your firm failed to establish an adequate quality control unit with the responsibility and authority to approve or reject all components, drug product containers, closures, in-process materials, packaging materials, labeling, and drug products (21 CFR 211.22(a)).

The records and information you provided demonstrate that your quality unit (QU) did not effectively exercise its responsibilities to oversee the quality of your drug manufacturing operations. Specifically, your QU did not adequately exercise its authority in the approval or rejection of components in your Materials System.

Your QU is responsible for fully exercising its authority and responsibilities. FDA is concerned that your QU may also not be conducting appropriate oversight regarding other CGMP operations, including Production, Facilities & Equipment, Laboratory Controls, and Packaging & Labelling Systems.

See FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations for help implementing quality systems and risk management approaches to meet the requirements of CGMP regulations 21 CFR, parts 210 and 211 at https://www.fda.gov/media/71023/download.

In response to this letter, provide:

• A comprehensive assessment and remediation plan to ensure your QU is given the authority and resources to effectively function. The assessment should also include, but not be limited to:

o A determination of whether procedures used by your firm are robust and appropriate o Provisions for QU oversight throughout your operations to evaluate adherence to appropriate practices o A complete and final review of each batch and its related information before the QU disposition decision o Oversight and approval of investigations and discharging of all other QU duties to ensure identity, strength, quality, and purity of all products

CGMP Consultant Recommended

Based upon the nature of the violations we identified at your firm, you should engage a consultant qualified as set forth in 21 CFR 211.34 to evaluate your operations and to assist your firm in meeting CGMP requirements if your firm intends to resume manufacturing drugs for the U.S. market. The qualified consultant should also perform a comprehensive six-system audit2 of your entire operation for CGMP compliance and evaluate the completion and efficacy of your CAPA before you pursue resolution of your firm’s compliance status with FDA.

Your use of a consultant does not relieve your firm’s obligation to comply with CGMP. Your firm’s executive management remains responsible for resolving all deficiencies and systemic flaws to ensure ongoing CGMP compliance.

Conclusion

The violations cited in this letter are not intended to be an all-inclusive list of violations that exist at your facility. You are responsible for investigating and determining the causes of any violations and for preventing their recurrence or the occurrence of other violations. FDA placed your firm on Import Alert 66-40 on May 8, 2023.

Correct any violations promptly. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may re-inspect to verify that you have completed corrective actions to any violations.

Failure to address violations may also cause FDA to withhold issuance of Export Certificates. FDA may withhold approval of new applications or supplements listing your firm as a drug manufacturer until any violations are completely addressed and we confirm your compliance with CGMP. We may inspect your facility to verify that you have completed corrective actions to address any violations.

This letter notifies you of our findings and provides you an opportunity to address the above deficiencies. After you receive this letter, respond to this office in writing within 30 working days. Specify what you have done to address any violations and to prevent their recurrence. In response to this letter, you may provide additional information for our consideration as we continue to assess your activities and practices. If you cannot complete corrective actions within 15 working days, state your reasons for delay and your schedule for completion.

Send your electronic reply to CDER-OC-OMQ-Communications@fda.hhs.gov. Identify your response with FEI #3015282935 and ATTN: Matthew R. Dionne, Pharm.D., Compliance Officer.

Sincerely, /S/

Francis Godwin Director Office of Manufacturing Quality Office of Compliance Center for Drug Evaluation and Research

CC (U.S. Agent via email): Registrar Corp. Drugs@registrarcorp.com

1 Components with higher risk of (b)(4) or (b)(4) contamination compared to other drug components.

2 i.e., Quality System, Facilities & Equipment System, Materials System, Production System, Packaging & Labeling System, and Laboratory Control System per FDA’s guidance document Quality Systems Approach to Pharmaceutical CGMP Regulations.

The Firm's Other Letters

Same company or the same FDA site, newest first

Recent Letters Citing Supplier controls

See them all

Record

Recipient
Teresa Neves
FDA site ID (FEI)
3015282935

Tags are assigned by Arca from the letter's text. A closeout letter means FDA found the firm's corrections adequate; no closeout does not mean the issues are unresolved. FDA warning letters

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.

Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.