Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.
FDA establishment 3031057987, Wheat Ridge, Colorado, United States. Part of PReye's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 1
Official action indicated: 1
Form 483s posted: 1
Warning letters: 1
Recalls since 2016: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.42(c)(10). Aseptic Processing Area Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
21 CFR 211.84(d)(1). Identity Testing of Each Component The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to aseptic processing of drug products.
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
There is no quality control unit.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports