FDA establishment 3016710931, Houston, Texas, United States. Part of Wells Pharma of Houston's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 3
Official action indicated: 1
Form 483s posted: 5
Warning letters: 1
Recalls since 2016: 2
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
FDCA 503B(a)(10)(A). Drug product labels, fails to include The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
21 CFR 211.125(a). Strict control not exercised over labeling issued Strict control is not exercised over labeling issued for use in drug product labeling operations.
FDCA 503B(b)(2)(A). All inclusive product report, not submitted Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Official Action Indicated (OAI)
Dec 14, 2022
Drugs · Drug Quality Assurance
3 cited references
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.42(a). Buildings of Suitable Size, Construction, Location Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Voluntary Action Indicated (VAI)
Jun 17, 2021
Drugs · Drug Quality Assurance
1 cited reference
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of 5 inspections, from the 483s FDA posted; newest first, the 4 newest
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity…
The written stability testing program is not followed.
Drug products failing to meet established specifications and quality control criteria are not rejected.
Strict control is not exercised over labeling issued for use in drug product labeling operations.
The responsibilities and procedures applicable to the quality control unit are not fully followed.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Strict control is not exercised over labeling issued for use in drug product labeling operations.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
The labels of your outsourcing facility's drug products do not include information required by section 503B(a)(10)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Your outsourcing facility has not submitted a report to FDA identifying a product compounded during the previous six months as required by section 503B(b)(2)(A) of the Federal Food, Drug, and Cosmetic Act (FD&C Act).
Routine inspection and checking of automatic and electronic equipment is not performed according to a written program designed to assure proper performance.
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
The responsibilities and procedures applicable to the quality control unit are not in writing.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports