FDA establishment 3014253278, Corona, California, United States. Part of CTK OTC Laboratories's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 4
Official action indicated: 2
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration and checking of automatic and mechanical equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Official Action Indicated (OAI)
Dec 31, 2024
Drugs · Drug Quality Assurance
4 cited references
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
21 CFR 211.194(a)(2). Suitability of testing methods verified The suitability of all testing methods is not verified under actual conditions of use.
21 CFR 211.192. No written record of investigation Written records are not always made of investigations into unexplained discrepancies.
21 CFR 211.110(a). Written in-process control procedures Written procedures are not established and followed that describe the in-process controls to be conducted on appropriate samples of in-process materials of each batch.
Official Action Indicated (OAI)
Mar 8, 2019
Drugs · Drug Quality Assurance
7 cited references
21 CFR 211.80(a). Written Procedures Not Followed Written procedures are not followed for the approval and rejection of components.
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.188(b)(12). Investigations made into any unexplained discrepancy Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
Voluntary Action Indicated (VAI)
Oct 22, 2018
Drugs · Drug Quality Assurance
11 cited references
21 CFR 211.22(c). Approve or reject procedures or specs The quality control unit lacks responsibility to approve all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing.
21 CFR 211.42(b). Product flow through building is inadequate The flow of components though the building is not designed to prevent contamination.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.42(c). Defined areas of adequate size for operations The separate or defined areas necessary to prevent contamination or mix-ups are deficient.
21 CFR 211.80(a). Written Procedures Not Followed Written procedures are not followed for the sampling, testing, approval and rejection of components.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports