FDA establishment 3012668529, Cheonan, Korea (the Republic of). Part of C&T Dream's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 2
Official action indicated: 1
Form 483s posted: 1
Warning letters: 1
Import refusals since 2024: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.46(b). Equipment for Environmental Control Equipment for adequate control over air pressure, micro-organisms, dust, humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
21 CFR 211.84(d)(2). Reports of Analysis (Components) Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
21 CFR 211.58. Buildings not maintained in good state of repair Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
21 CFR 211.166(b). Tentative expiration date Where data from accelerated studies was used to project a tentative expiration date beyond a date supported by actual shelf life studies, there were no stability studies and drug product testing at appropriate intervals conducted until the tentative expiration date was verified or the appropriate expiration date determined.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.194(a)(4). Complete Test Data Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
21 CFR 211.84(c)(2). Appropriate Opening of Component Containers The containers of components, or drug product containers or closures which are sampled are not opened in a manner to prevent contamination of their contents, contamination of other components, contamination of other drug product containers and contamination of other closures.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
Official Action Indicated (OAI)
Jul 21, 2017
Drugs · Drug Quality Assurance
6 cited references
21 CFR 211.84(d)(1). Component identity verification Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
21 CFR 211.188(b)(12). Investigations made into any unexplained discrepancy Batch production and control records do not include the results of any investigation made into any unexplained discrepancy, whether or not the batch of drug product had already been distributed.
21 CFR 211.160(b)(2). In-process sample representation/identification In-process samples are not representative.
21 CFR 211.160(b)(3). Drug product sample Drug product samples are not representative of the entire batch.
21 CFR 211.166(b). Accelerated stability studies Accelerated stability studies, combined with basic stability information, used to support tentative expiration dates are not supported with ongoing full shelf life studies.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
Laboratory records are deficient in that they do not include a complete record of all data obtained during testing.
Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in- process material and the drug…
Where data from accelerated studies was used to project a tentative expiration date beyond a date supported by actual shelf life studies, there were no stability studies and drug product testing at appropriate intervals conducted until…
Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Equipment for adequate control over air pressure, micro-organisms, dust, humidity and temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
Buildings used in the manufacturing, processing, packing and holding of a drug product are not maintained in a good state of repair.
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and…
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
The containers of components, or drug product containers or closures which are sampled are not opened in a manner to prevent contamination of their contents, contamination of other components, contamination of other drug product…
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports