FDA establishment 3012271380, Richmond, Canada. Part of Deserving Health International's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, its recalls since 2016, and the shipments FDA refused at the border.
21 CFR 211.84(d)(1). Component identity verification Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
21 CFR 211.182. Written records kept in individual logs Written records of major equipment maintenance and use are not included in individual equipment logs.
21 CFR 211.134(c). Examinations documented The results of the examination of the packaged and labeled products were not documented in the batch production or control records.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.46(b). Equipment for Environmental Control Equipment for adequate control over air pressure is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
21 CFR 211.122(a). Written procedures not followed Written procedures for the receipt of packaging and labeling materials are not followed.
21 CFR 211.122(d). Label storage access limited to authorized personnel Access to the storage area for labels and labeling materials is not limited to authorized personnel.
21 CFR 211.80(a). Written Procedures Not Followed Written procedures are not followed for the receipt of components.
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
21 CFR 211.150(b). Distribution Recall System The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
21 CFR 211.113(a). Procedures for non-sterile drug products Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
21 CFR 211.56(c). Written procedures lacking for use of pesticides etc. Written procedures are lacking for the use of rodenticides, insecticides and fungicides designed to prevent the contamination of equipment, components, drug product containers, closures and drug products.
21 CFR 211.101(d). Component addition checked by 2nd person Each component is not added to a batch by one person and verified by a second person.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.42(d). Penicillin processing area not kept separate The operations relating to the manufacture, processing and packing of penicillin are not performed in facilities separate from those used for other drug products for human use.
21 CFR 211.160(a). Lab controls established, including changes The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit.
Official Action Indicated (OAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports