FDA establishment 3012088459, Janesville, Wisconsin, United States. Part of DeVere Manufacturing's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 2
Official action indicated: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.166(a). Written program not followed The written stability testing program is not followed.
21 CFR 211.84(d)(2). Establish reliability of supplier's C of A Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.188(b). Batch production and Batch Control Record Requirements The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing, packing and holding.
21 CFR 211.84(d)(2). Component identification test Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
21 CFR 211.100(a). Absence of Written Procedures Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Official Action Indicated (OAI)
Feb 2, 2018
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports