Logos are each company's own site icon, matched by name through Wikidata, or logos provided by Logo.dev.Company names and logos identify the companies in public FDA and registry records and do not imply endorsement.
FDA establishment 3012038236, Austin, Texas, United States. Part of Stonegate Pharmacy's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 3
Official action indicated: 1
Form 483s posted: 3
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 0 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
FDCA 501(a)(2)(A). Cleanliness, ISO-classified areas The ISO 5 classified aseptic processing areas had difficult to clean and particle-generating equipment or surface.
FDCA 501(a)(2)(A). Hazardous drugs, prevention of cross-contamination You produced hazardous drugs without providing adequate containment and segregation to prevent cross-contamination.
FDCA 501(a)(2)(A). Disinfecting materials, aseptic processing area Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.
FDCA 501(a)(2)(A). Improper gowning, contamination Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated.
Voluntary Action Indicated (VAI)
Jun 11, 2018
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Mar 2, 2016
Drugs · Drug Quality Assurance
12 cited references
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.94(b). Protection from external factors Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.113(b). Validation lacking for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
21 CFR 211.167(a). Sterility/pyrogen-free testing Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
21 CFR 211.94(c). Containers & Closures Clean, Sterilized, Pyrogen-free Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
21 CFR 211.28(a). Clothing appropriate for duties performed Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 3 inspections, from the 483s FDA posted; newest first
Stonegate Pharmacy LP 2501 W William Cannon Dr Ste 203 You produced hazardous drugs without providing adequate containment and segregation to prevent cross-contamination.
Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.
I witnessed your firm's failure to properly store unsealed prefilters awaiting installation into your laminar airflow hood ISO 5 environment, (b) (4) (b) (4), serial #(b) (4), model #(b)(4).
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess.
Media fills were not performed that closely simulate aseptic production operations incorporating as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations.
Personnel hand washing procedure was conducted in a way that may have cause the gowning apparel to become contaminated.
(b) (4) are not used properly to verify the adequacy of the sterilization (b) (4) a) Your firm (b) (4) sterilizes vials of Testosterone in (b) (4) and (b) (4) .
Stock solutions used in the preparation of sterile finished drug products are not (b) (4) sterilized nor stored in sterile containers.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Clothing of personnel engaged in the manufacturing and processing of drug products is not appropriate for the duties they perform.
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Drug product containers and closures were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
There is no written testing program designed to assess the stability characteristics of drug products.
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Routine calibration of automatic, mechanical, and electronic equipment is not performed according to a written program designed to assure proper performance.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports