FDA establishment 3011967886, Lowellville, Ohio, United States. Part of RC Outsourcing's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 6
Official action indicated: 4
Form 483s posted: 8
Warning letters: 1
Recalls since 2016: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 3 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.192. Extent of discrepancy, failure investigations Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.84(d)(2). Reports of Analysis (Components) Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
Official Action Indicated (OAI)
Sep 27, 2024
Drugs · Drug Quality Assurance
8 cited references
21 CFR 211.100(b). SOPs not followed / documented Written production and process control procedures are not followed in the execution of production and process control functions.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.194(a)(8). Second person sign off Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
21 CFR 211.198(a). Quality Control Review Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
21 CFR 211.170(b). Reserve samples identified, representative, stored Reserve drug product samples are not appropriately identified and representative of each lot or batch of drug product.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that conform to appropriate standards of identity, strength, quality and purity.
Official Action Indicated (OAI)
Sep 23, 2022
Drugs · Drug Quality Assurance
9 cited references
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine of equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.28(a). Protective Apparel Not Worn Protective apparel is not worn as necessary to protect drug products from contamination.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.100(a). Changes to Procedures Not Reviewed, Approved Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
21 CFR 211.42(b). Product flow through building is inadequate The flow of components, drug product containers, closures, in-process materials and drug products through the building is not designed to prevent contamination.
Official Action Indicated (OAI)
Feb 8, 2019
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Mar 31, 2017
Drugs · Drug Quality Assurance
9 cited references
21 CFR 211.167(a). Sterility/pyrogens - test methods written, followed Test procedures relative to appropriate laboratory testing for sterility are not followed.
21 CFR 211.167(a). Sterility/pyrogen-free testing Each batch of drug product purporting to be pyrogen-free is not laboratory tested to determine conformance to such requirements.
21 CFR 211.165(e). Test methods The accuracy and reproducibility of test methods have not been established and documented.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.28(a). Clothing appropriate for duties performed Clothing of personnel engaged in the manufacturing, processing and packing of drug products is not appropriate for the duties they perform.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and written.
Official Action Indicated (OAI)
Feb 9, 2016
Drugs · Drug Quality Assurance
8 cited references
FDCA 503B(a)(10). Drug product label, outsourcer facility The labels of your outsourcing facility?s drug products are deficient.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
21 CFR 820.198(a). Complaints Complaint files are not maintained. Specifically ***
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed .
21 CFR 211.42(a). Buildings of Suitable Size, Construction, Location Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.167(a). Sterility/pyrogen-free testing Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of 8 inspections, from the 483s FDA posted; newest first, the 4 newest
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic and sterilization process.
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
There is a lack of written procedures assigning responsibility, providing cleaning schedules and describing in sufficient detail the methods, equipment and materials to be used for sanitation.
Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
Drug product expiration dates are not related to the storage conditions stated on the labeling, as determined by stability studies.
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or…
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and…
Routine calibration of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Batch production and control records do not include complete information relating to the production and control of each batch.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Laboratory records do not include the initials or signature of a second person showing that the original records have been reviewed for accuracy, completeness and compliance with established standards.
There is a failure to thoroughly review the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that conform to appropriate standards of identity, strength, quality and purity.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Complaint procedures are deficient in that they do not include provisions that allow for the review and determination of an investigation by the quality control unit.
Reserve drug product samples are not appropriately identified and representative of each lot or batch of drug product.
Written production and process control procedures are not followed in the execution of production and process control functions.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Protective apparel is not worn as necessary to protect drug products from contamination.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
The flow of components, drug product containers, closures, in-process materials and drug products through the building is not designed to prevent contamination.
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit.
Routine of equipment is not performed according to a written program designed to assure proper performance.
Your outsourcing facility has not submitted an adverse event report to FDA in accordance with the content and format requirements established through guidance or regulation under 21 CFR 310.305 as required by section 503B(b)(5).
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports