FDA establishment 3011853060, Navi Mumbai, India. Part of Kilitch Healthcare India's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, its recalls since 2016, and the shipments FDA refused at the border.
Inspections: 1
Official action indicated: 1
Form 483s posted: 2
Warning letters: 1
Recalls since 2016: 1
Import refusals since 2014: 16
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.84(d)(1). Component identity verification Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
21 CFR 211.56(a). Sanitation--buildings not clean, free of infestation Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
21 CFR 211.100(a). Changes to Procedures Not Reviewed, Approved Changes to written procedures are not reviewed and approved by the quality control unit.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.166(a)(3). Valid stability test methods The written stability program for drug products does not include meaningful test methods.
21 CFR 211.113(b). Validation lacking for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.160(a). Following/documenting laboratory controls Established test procedures are not documented at the time of performance.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 2 inspections, from the 483s FDA posted; newest first
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and…
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Established test procedures are not documented at the time of performance.
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.Testing of (b) (4) for (b) (4) is not conducted on each shipment of each lot.Supplier lot (b) (4) was…
Batch production and control records do not include complete information relating to the production and control of each batch.
The written stability program for drug products does not include meaningful test methods.
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Changes to written procedures are not reviewed and approved by the quality control unit.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and…
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
Established test procedures are not documented at the time of performance.
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
Batch production and control records do not include complete information relating to the production and control of each batch.
The written stability program for drug products does not include meaningful test methods.
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Changes to written procedures are not reviewed and approved by the quality control unit.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports