| Jul 19, 2017 | Drugs ยท Drug Quality Assurance | 32 cited references- 21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use and cleaning and maintenance.
- 21 CFR 211.87. Retest of approved components/containers/closures Approved components, drug product containers and closures are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
- 21 CFR 211.105(b). Distinctive ID or code not recorded in batch record The batch records do not record the distinctive identification number and name of equipment to identify major equipment to show the specific equipment used in the manufacture of a batch of a drug product.
- 21 CFR 211.86. Rotation of components/containers/closures There is a lack of rotation so that the oldest approved stock of components, drug product containers and closures is used first.
- 21 CFR 211.22(c). Approve or reject procedures or specs The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality and purity of drug products.
- 21 CFR 211.170(a). Active ingredient retained sample kept A sample which is representative of each lot in each shipment of each active ingredient is not retained.
- 21 CFR 211.184(c). Individual inventory record Records fail to include an individual inventory record of each component, reconciliation of the use of each component, drug product container and drug product closure with sufficient information to allow determination of any associated batch or lot of drug product.
- 21 CFR 211.170(b). Annual visual exams of drug products Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
- 21 CFR 211.165(c). Sampling and testing plans not described Sampling and testing plans for drug products are not described in written procedures which include the method of sampling and number of units per batch to be tested.
- 21 CFR 211.82(a). Examination on receipt, before acceptance Each container or grouping of containers of components, drug product containers and closures is not examined visually upon receipt and before acceptance for appropriate labeling as to contents, container damage, broken seals and contamination.
- 21 CFR 211.80(a). Procedures To Be in Writing Written procedures are lacking which describe in sufficient detail the receipt, identification, storage, handling, sampling, testing, approval and rejection of components, drug product containers and closures.
- 21 CFR 211.137(a). Expiration date lacking Drug products do not bear an expiration date determined by appropriate stability data to assure they meet applicable standards of identity, strength, quality and purity at the time of use.
- 21 CFR 211.42(b). Adequate space lacking to prevent mix-ups and contamination The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between different components, drug product containers, closures, labeling, in-process materials and drug products and to prevent contamination.
- 21 CFR 211.84(d)(1). Component identity verification Drug product component testing is deficient in that at least one specific test to verify the identity of each component is not performed.
- 21 CFR 211.22(a). Authority lacking to review records, investigate errors The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
- 21 CFR 211.160(b)(4). Calibration - at intervals, written program, remedial action The calibration of instruments and apparatus is not done at suitable intervals in accordance with an established written program and with provisions for remedial action in the event accuracy and/or precision limits are not met.
- 21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
- 21 CFR 211.22(b). Adequate lab facilities not available Adequate lab facilities for testing and approval or rejection of components, drug product containers, closures, packaging materials, in-process materials and drug products are not available to the quality control unit.
- 21 CFR 211.186(a). Signature and checking of records -- 2 persons The master production and control records for each batch size of drug product are not prepared, dated, and signed by one person with a full handwritten signature and independently checked, dated, and signed by a second person.
- 21 CFR 211.42(c)(2). Rejected Material Area Separate or defined areas to prevent contamination or mix-ups are deficient regarding operations related to the holding of rejected components, drug product containers, closures and labeling before disposition.
- 21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
- 21 CFR 211.196. Distribution Record Requirements Distribution records do not contain the lot or control number of drug product.
- 21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
- 21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
- 21 CFR 211.100(a). Absence of Written Procedures There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
- 21 CFR 211.182. Written records kept in individual logs Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
- 21 CFR 211.56(a). Trash and organic waste timely disposal There is no provision to hold and dispose of trash in a timely and sanitary manner.
- 21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
- 21 CFR 211.130. Procedures are written, and followed Procedures designed to assure that correct labels, labeling and packaging materials are used for drug products are not written.
- 21 CFR 211.111. Establishment of time limitations Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
- 21 CFR 211.142(a). Quarantine - actual practice Drug products are not quarantined before being released by the quality control unit.
- 21 CFR 211.84(d)(2). Establish reliability of supplier's C of A Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
| Official Action Indicated (OAI) |