FDA establishment 3010241801, Hattiesburg, Mississippi, United States. Part of Vital Care Compounder's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 3
Official action indicated: 3
Form 483s posted: 3
Warning letters: 1
Recalls since 2016: 4
Inspections by fiscal year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
20182018Inspections0
120192019Inspections1vs 2018+1
20202020Inspections0vs 2019−1
20212021Inspections0vs 2020+0
20222022Inspections0vs 2021+0
120232023Inspections1vs 2022+1
20242024Inspections0vs 2023−1
20252025Inspections0vs 2024+0
20262026Inspections0vs 2025+0
20272027 to dateInspections0
Most Cited at This Site
Inspections citing each reference
FDCA 501(a)(2)(A): Hazardous drugs, prevention of cross-contamination1FDCA 501(a)(2)(A): Hazardous drugs, prevention of cross-contaminationValue1
FDCA 501(a)(2)(A). Hazardous drugs, prevention of cross-contamination You produced hazardous drugs without providing adequate segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.
FDCA 501(a)(2)(A). Insufficient cycle parameters, heat sterilization of product The cycle parameters (temperature, pressure and time) used for heat sterilization of product intended to be sterile were not lethal to heat-resistant microorganisms.
FDCA 501(a)(2)(A). Disinfecting and cleaning agents, ISO 5 area Disinfecting agents and cleaning pads and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
FDCA 501(a)(2)(A). Personnel habits, contamination Personnel did not disinfect and change gloves frequently enough to prevent contamination.
FDCA 501(a)(2)(A). Personnel contact on container or closure Personnel used a non-sterile tool on and manually contacted the inner surface of the container or closure.
FDCA 501(a)(2)(A). Actionable microbial contamination, ISO 5 area You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
FDCA 501(a)(2)(A). Final/intermediate container and closure, sterile drug product The final containers/closures used for drug product intended to be sterile were not sterilized and de-pyrogenated.
FDCA 501(a)(2)(A). Cleanliness, ISO-classified areas The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
Official Action Indicated (OAI)
May 16, 2019
Drugs · Drug Quality Assurance
10 cited references
21 CFR 211.28(a). Clothing appropriate for duties performed Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.
21 CFR 211.166(a)(3). Valid stability test methods The written stability program for drug products does not include meaningful and specific test methods.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.42(a). Buildings of Suitable Size, Construction, Location Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size to facilitate cleaning, maintenance, and proper operations.
21 CFR 211.67(c). Cleaning/maintenance records not kept Records are not kept for the maintenance, sanitizing and inspection of equipment.
21 CFR 211.100(a). Absence of Written Procedures There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
21 CFR 211.165(b). Microbiological testing Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Official Action Indicated (OAI)
Jul 7, 2016
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 3 inspections, from the 483s FDA posted; newest first
You did not make adequate product evaluation and take remedial action where actionable microbial contamination was found to be present in the ISO 5 classified aseptic processing area during aseptic production.
The cycle parameters ( (b) (4) ) used for (b)(4) sterilization of product intended to be sterile were not lethal to heat-resistant microorganisms.
The final containers/closures used for drug product intended to be sterile were not sterilized and (b)(4).
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
Disinfecting agents and cleaning pads and cleaning wipes used in the ISO 5 classified aseptic processing areas were not sterile.
Personnel used a non-sterile tool on and manually contacted the inner surface of the container or closure.
Personnel did not disinfect and change gloves frequently enough to prevent contamination.
You produced hazardous drugs without providing adequate segregation, cleaning of work surfaces and cleaning of utensils to prevent cross-contamination.
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations.
In addition, your firm (b) (4) sterilized a portion of the media fill vials which fails to evaluate the operator’s aseptic technique.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Clothing of personnel engaged in the manufacturing, processing, packing and holding of drug products is not appropriate for the duties they perform.
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable size to facilitate cleaning, maintenance, and proper operations.
The written stability program for drug products does not include meaningful and specific test methods.
Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
Records are not kept for the maintenance, sanitizing and inspection of equipment.
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Container closure systems do not provide adequate protection against foreseeable external factors in storage and use that can cause deterioration or contamination of the drug product.
Clothing of personnel engaged in the manufacturing, processing, and packing of drug products is not appropriate Marvin D. Jones /
Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
Routine calibration of equipment is not performed according to a written program designed to assure proper performance.
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Results of stability testing are not used in determining expiration dates.
There is no written testing program designed to assess the stability characteristics of drug products.
Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports