FDA establishment 3010164449, Phoenix, Arizona, United States. Part of AnuMed International's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 1
Official action indicated: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
Drugs · Drug Quality AssuranceDrugs · Unapproved and Misbranded Drugs
6 cited references
21 CFR 211.166(b). Adequate number of batches on stability An adequate number of batches of each drug product are not tested to determine an appropriate expiration date.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
21 CFR 211.56(a). Sanitation--buildings not clean, free of infestation Buildings used in the manufacture, processing, packing or holding of drug products are not maintained in a clean and sanitary condition.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
21 CFR 211.100(a). Absence of Written Procedures Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
Official Action Indicated (OAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports