FDA establishment 3009250196, Daman, India. Part of Patcos Cosmetics Pvt's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 3
Official action indicated: 1
Warning letters: 2
Import refusals since 2024: 15
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
21 CFR 211.160(a). Lab controls established, including changes The establishment of test procedures including any changes thereto, are not reviewed and approved by the quality control unit.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in current good manufacturing practices.
Voluntary Action Indicated (VAI)
Sep 20, 2017
Drugs · Drug Quality Assurance
7 cited references
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.22(a). Authority lacking to review records, investigate errors The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
21 CFR 211.52. Washing and toilet facilities are deficient Washing and toilet facilities lack hot and cold water, air driers or single-service towels and cleanliness.
21 CFR 211.188(a). Accurate reproduction The batch production and control records are deficient in that they are not an accurate reproduction of the appropriate master production or control record.
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not established and followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
21 CFR 211.67(b). Written procedures fail to include Written procedures for cleaning and maintenance fail to include assignment of responsibility, maintenance and cleaning schedules, description in sufficient detail of methods, equipment and materials used and description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports