FDA establishment 3009248035, Chatsworth, California, United States. Part of TSDR Pharmacy's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records are not prepared for each batch of drug product produced and do not include complete information relating to the production and control of each batch.
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components, drug product containers, closures and drug products conform to appropriateโฆ
There is no quality control unit.
Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established and written.
Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and of adequate size to facilitate operations for its intended use and cleaning and maintenance.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports