FDA establishment 3008927138, Neenah, Wisconsin, United States. Part of Morton Drug Company dba Morton LTC's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
21 CFR 211.113(b). Validation lacking for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
21 CFR 211.28(a). Protective Apparel Not Worn Protective apparel is not worn as necessary to protect drug products from contamination.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.42(c)(10)(vi). Equipment to control conditions Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.166(a). Results not used for expiration dates, storage cond. Results of stability testing are not used in determining appropriate storage conditions and expiration dates.
Official Action Indicated (OAI)
May 20, 2011
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of 2 inspections, from the 483s FDA posted; newest first
You produced beta-lactam drugs without providing adequate cleaning of work surfaces to prevent cross-contamination.
Materials or supplies were not disinfected prior to entering the aseptic processing areas.
Media fills were not performed that closely simulate aseptic production operations incorporating, as appropriate, worst-case activities and conditions that provide a challenge to aseptic operations.
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
Results of stability testing are not used in determining appropriate storage conditions and expiration dates.
Protective apparel is not worn as necessary to protect drug products from contamination.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile do not include adequate validation of the sterilization process.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports