FDA establishment 3007953761, Statesville, North Carolina, United States. Part of Sklar Personal Care's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 2
Official action indicated: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.68(a). Written calibration / inspection records not kept Records of the calibration checks and inspections of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.100(a). Absence of Written Procedures Your firm failed to establish written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
21 CFR 211.84(d)(1). Identity Testing of Each Component The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
21 CFR 211.22(a). Authority lacking to review records, investigate errors The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration, inspection and checking of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
Official Action Indicated (OAI)
Mar 7, 2018
Drugs · Drug Quality Assurance
8 cited references
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.22(a). Approve or reject components, products The quality control unit lacks the responsibility and authority to approve all components, drug product containers, closures and labeling.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.
21 CFR 211.100(b). SOPs not followed / documented Written production and process control procedures are not documented at the time of performance.
21 CFR 211.192. Quality control unit review of records Drug product production and control records, are not reviewed and approved by the quality control unit to determine compliance with all established, approved written procedures before a batch is released or distributed.
21 CFR 211.188(b)(11). Identification of Persons Performing Significant Steps The batch production and control records are deficient in that they do not include identification of persons performing each significant step in the operation.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.192. No written record of investigation Written records are not made of investigations into unexplained discrepancies.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports