FDA establishment 3007187282, Malpur, India. Part of Panacea Biotec's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 9
Official action indicated: 3
Form 483s posted: 1
Warning letters: 1
Import refusals since 2014: 3
Inspections by fiscal year
FY2018 to FY2027 to date; 3 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.113(b). Validation lacking for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.25(a). Training , Education , Experience overall Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.
Official Action Indicated (OAI)
Jun 8, 2022
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Feb 20, 2020
Drugs · Drug Quality Assurance
7 cited references
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.167(a). Sterility/pyrogens - test methods written, followed Test procedures relative to appropriate laboratory testing for sterility and pyrogens are not written.
21 CFR 211.100(a). Absence of Written Procedures There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Official Action Indicated (OAI)
Apr 30, 2019
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Dec 13, 2017
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Dec 11, 2015
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Oct 25, 2013
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Sep 7, 2012
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Nov 13, 2009
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established, written and followed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Employees engaged in the manufacture and processing of a drug product lack the training required to perform their assigned functions.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling…
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process…
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design and suitably located to facilitate operations for its intended use and cleaning and maintenance.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports