FDA establishment 3006613129, Woonsocket, Rhode Island, United States. Part of Aidance Scientific's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 3
Official action indicated: 0
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 0 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
21 CFR 211.182. Written records kept in individual logs Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.170(b). Annual visual exams of drug products Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
Voluntary Action Indicated (VAI)
Aug 31, 2018
Drugs · Drug Quality Assurance
12 cited references
21 CFR 211.46(b). Equipment for Environmental Control Equipment for adequate control over temperature is not provided when appropriate for the manufacture, processing, packing or holding of a drug product.
21 CFR 211.165(b). Microbiological testing Each batch of drug product required to be free of objectionable microorganisms is not tested through appropriate laboratory testing.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not established for evaluations done at least annually and including provisions for a review of complaints, recalls and investigations conducted for each drug product.
21 CFR 211.84(d)(3). Container/Closure Written Test Procedure Drug product container and closure test procedures are deficient in that are not tested for conformance in accordance with appropriate written procedures.
21 CFR 211.84(d)(2). Establish reliability of supplier's C of A Establishment of the reliability of the component supplier's report of analyses is deficient in that the test results are not appropriately validated at appropriate intervals.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.84(d)(1). Identity Testing of Each Component The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.170(a). Active ingredient retained sample kept A sample which is representative of each lot in each shipment of each active ingredient is not retained.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications and identity and strength of each active ingredient prior to release.
Voluntary Action Indicated (VAI)
Mar 30, 2015
Drugs · Drug Quality Assurance
9 cited references
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing .
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.198(a). Complaint Handling Procedure Procedures describing the handling of written and oral complaints related to drug products are not written or followed .
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.25(a). GMP Training Frequency GMP training is not conducted on a continuing basis to assure that employees remain familiar with CGMP requirements applicable to them.
21 CFR 211.204. Returned drug procedures in writing and followed Procedures describing the holding and testing and reprocessing of returned drug products are not in writing .
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.186(b)(9). Manufacturing Instructions and Specifications The master production and control records are deficient in that they do not include complete manufacturing and control and instructions and procedures .
21 CFR 211.186(a). Written procedures followed Procedures for the preparation of master production and control records are not described in a written procedure .
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports