FDA establishment 3005664940, Perrysburg, Ohio, United States. Part of Buderer Drug's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
21 CFR 211.87. Retest of approved components/containers/closures Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.167(a). Sterility/pyrogen-free testing Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.42(c)(10)(iii). Air Supply Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 2 inspections, from the 483s FDA posted; newest first
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess.
Personnel donned gowning apparel improperly, in a way that may have caused the gowning apparel to become contaminated and were observed with exposed skin during aseptic processing.
Pressure differentials between areas with different air classifications were not monitored prior to or during sterile drug production.
Aseptic processing areas are deficient regarding air supply that is filtered through high-efficiency particulate air filters under positive pressure.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Equipment and utensils are not maintained and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Approved components are not retested or reexamined as appropriate for identity, strength, quality and purity after storage for long periods with subsequent approval or rejection by the quality control unit.
Each batch of drug product purporting to be sterile and pyrogen-free is not laboratory tested to determine conformance to such requirements.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports