FDA establishment 3005057567, Grand Prairie, Texas, United States. Part of Analytical Food Laboratories's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 5
Official action indicated: 2
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Official Action Indicated (OAI)
May 17, 2024
Drugs · Drug Quality Assurance
7 cited references
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.160(b)(4). Establishment of calibration procedures Procedures describing the calibration of instruments, apparatus, gauges and recording devices are not written or followed and deficiently written or followed.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.25(a). Training , Education , Experience overall Employees engaged in the of a drug product lack the required to perform their assigned functions.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that components, drug product containers, closures, in-process materials, labeling and drug products conform to appropriate standards of identity, strength, quality and purity.
Official Action Indicated (OAI)
Apr 7, 2017
Drugs · Drug Quality Assurance
5 cited references
21 CFR 211.160(a). Following/documenting laboratory controls Established test procedures and laboratory control mechanisms are not followed and documented at the time of performance.
21 CFR 211.198(a). Procedures to be written and followed Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
21 CFR 211.192. No written record of investigation Written records are not made of investigations into unexplained discrepancies.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Electronic records are used, but they do not meet systems validation, retention, system access limitation, audit trail, personnel qualifications, employee accountability/responsibility policy and systems documentation control requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
Voluntary Action Indicated (VAI)
Nov 9, 2010
Drugs · Drug Quality Assurance
1 cited reference
21 CFR 211.160(a). Following/documenting laboratory controls Established laboratory control mechanisms are not followed and documented at the time of performance.
Voluntary Action Indicated (VAI)
Mar 10, 2009
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports