FDA establishment 3004737602, Brampton, Canada. Part of LEC Custom Products's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 4
Official action indicated: 1
Warning letters: 2
Import refusals since 2014: 19
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.22(a). Authority lacking to review records, investigate errors The quality control unit lacks authority to review production records to assure that no errors have occurred and fully investigate errors that have occurred.
21 CFR 211.80(d). Status of Each Lot Identified Each lot of components, drug product containers and closures was not appropriately identified as to its status in terms of being quarantined, approved or rejected.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.84(d)(2). Reports of Analysis (Components) Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without performing at least one specific identity test on each component and establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.110(a). Written in-process control procedures Written procedures are not established and followed that describe the in-process controls, tests and examinations to be conducted on appropriate samples of in-process materials of each batch.
21 CFR 211.101(a). Batches Formulated to less than 100% Written production and control procedures include batches formulated with the intent to provide less than 100 percent of the labeled or established amount of active ingredient.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration and checking of mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.188(b). Batch production and Batch Control Record Requirements The batch production and control records are deficient in that they do not include documentation of the accomplishment of each significant step in manufacturing, processing and packing.
21 CFR 211.103. Actual vs. theoretical yields not determined Actual yield and percentages of theoretical yield are not determined at the conclusion of each appropriate phase of manufacturing, processing and packaging of the drug product.
21 CFR 211.22(a). Approve or reject components, products The quality control unit lacks the responsibility and authority to approve and reject all drug product containers, closures, in process materials and drug products.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.80(b). Handling and Storage to Prevent Contamination There was a failure to handle and store components at all times in a manner to prevent contamination.
21 CFR 211.188(b)(11). Identification of Persons Performing Significant Steps The batch production and control records are deficient in that they do not include identification of persons performing each significant step in the operation.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.150(b). Distribution Recall System The distribution system is deficient in that each lot of drug product cannot be readily determined to facilitate its recall if necessary.
21 CFR 211.80(d). Identification of Each Lot in Each Shipment Each lot in each shipment received was not identified with a distinctive code for each container or grouping of containers for components, drug product containers and closures.
21 CFR 211.160(a). Following/documenting laboratory controls Established specifications, sampling plans, test procedures and laboratory control mechanisms are not followed and documented at the time of performance.
21 CFR 211.182. Written records kept in individual logs Written records of major equipment cleaning, maintenance and use are not included in individual equipment logs.
21 CFR 211.101(b). Measured components for manufacturing Components for drug product manufacturing are not weighed and measured.
21 CFR 211.198(a). Procedures to be written and followed Procedures describing the handling of all written and oral complaints regarding a drug product are not established, written and followed.
Official Action Indicated (OAI)
Dec 8, 2017
Drugs · Drug Quality Assurance
10 cited references
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.100(a). Absence of Written Procedures There are no written procedures for production and process controls designed to assure that the drug products have the identity, strength, quality, and purity they purport or are represented to possess.
21 CFR 211.110(c). In-process materials characteristics testing In-process materials are not tested for identity, strength, quality and purity and approved or rejected by the quality control unit during the production process and after storage for long periods.
21 CFR 211.101(d). Verification of component addition Each component is not added to the batch by one person and verified by a second person..
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration, inspection and checking of electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.42(c)(5). Mfg / Processing Operations Area Separate or defined areas to prevent contamination or mix-ups are deficient regarding the manufacturing and processing operations.
21 CFR 211.84(d)(2). Testing Each Component for Conformity with Specs Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in the particular operations they perform as part of their function, current good manufacturing practices and written procedures required by current good manufacturing practice regulations.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned, maintained and sanitized at appropriate intervals to prevent malfunctions and contamination that would alter the safety, identity, strength, quality or purity of the drug product.
Voluntary Action Indicated (VAI)
Mar 27, 2015
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Dec 15, 2011
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports