FDA establishment 3004555163, Jiutepec, Mexico. Part of Degasa S.A. de C.V.'s FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 2
Official action indicated: 2
Warning letters: 1
Recalls since 2016: 1
Import refusals since 2014: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.80(b). Handling and Storage to Prevent Contamination There was a failure to handle and store components at all times in a manner to prevent contamination.
21 CFR 211.166(a)(1). Sample size - test intervals The written stability program for drug products does not include test intervals based on statistical criteria for each attribute examined to assure valid estimates of stability.
21 CFR 211.84(b). Representative Samples Representative samples are not taken of each shipment of each lot of components for testing or examination.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use and cleaning and maintenance.
21 CFR 211.194(a)(8). Identification of Person Performing Review of Lab Records Laboratory records are deficient in that they do not include the initials and signature of the second person reviewing the record for accuracy.
21 CFR 211.42(a). Buildings of Suitable Size, Construction, Location Buildings used in the manufacture, processing, packing, or holding of a drug product do not have the suitable construction to facilitate cleaning, maintenance, and proper operations.
21 CFR 211.170(b). Investigation of reserve sample deterioration Evidence of reserve drug product sample deterioration was not recorded and maintained with other stability data.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.25(c). Inadequate number of personnel The number of qualified personnel is inadequate to perform and supervise the processing of each drug product.
Official Action Indicated (OAI)
Sep 8, 2017
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports