Inspections: 2
Official action indicated: 1
Warning letters: 1
Import refusals since 2014: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.84(d)(2). Component identification test Specific identification tests are not conducted on components that have been accepted based on the supplier's report of analysis.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
21 CFR 211.100(a). Absence of Written Procedures Your firm failed to establish adequate written procedures for production and process controls designed to assure that the drug products have the identity, strength, purity, and quality that they are purported or represented to possess.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
Official Action Indicated (OAI)
Sep 16, 2016
Drugs · Drug Quality Assurance
3 cited references
21 CFR 211.160(a). Lab controls established, including changes The establishment of laboratory control mechanisms including any changes thereto, are not drafted by the appropriate organizational unit and reviewed and approved by the quality control unit.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
21 CFR 211.186(a). Written procedures followed Procedures for the preparation of master production and control records are not described in a written procedure and followed.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports