FDA establishment 3003821988, Bengaluru, India. Part of Somerset Therapeutics Private's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 10
Official action indicated: 4
Form 483s posted: 1
Warning letters: 2
Recalls since 2016: 1
Import refusals since 2014: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 3 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Official Action Indicated (OAI)
Feb 19, 2020
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Jul 23, 2019
Drugs · Drug Quality Assurance
1 cited reference
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
Voluntary Action Indicated (VAI)
Dec 5, 2017
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Apr 24, 2017
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Aug 20, 2013
Drugs · Drug Quality Assurance
15 cited references
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.25(a). Training , Education , Experience overall Employees engaged in the processing, packing, and holding of a drug product lack the training required to perform their assigned functions.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.25(a). GMP Training Frequency GMP training is not conducted on a continuing basis and with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
21 CFR 211.160(a). Deviations from laboratory control requirements Deviations from written test procedures and laboratory mechanisms are not justified.
21 CFR 211.182. Written records kept in individual logs Written records of major equipment cleaning and use are not included in individual equipment logs.
21 CFR 211.110(a). Written in-process control procedures Written procedures are not followed that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into unexplained discrepancies do not always include the conclusions and follow-up.
21 CFR 211.67(c). Cleaning/maintenance records not kept Records are not kept for the cleaning of equipment.
21 CFR 211.160(a). Following/documenting laboratory controls Established test procedures and laboratory control mechanisms are not followed.
21 CFR 211.165(e). Test methods The accuracy and sensitivity of test methods have not been established.
21 CFR 211.56(b). Written sanitation procedures not followed Written procedures for sanitation are not followed.
21 CFR 211.100(b). SOPs not followed / documented Written production and process control procedures are not followed in the execution of production and process control functions.
21 CFR 211.56(b). Written sanitation procedures lacking There is a lack of written procedures describing in sufficient detail the methods, equipment and materials to be used for sanitation.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
Voluntary Action Indicated (VAI)
Sep 20, 2011
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Mar 31, 2009
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
There is a failure to submit a field alert report (FAR) to FDA within 3 working days of receiving information concerning bacteriological contamination in the distributed drug product.
There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile did not include adequate validation of the aseptic process.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established and followed.
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the room and equipment to produce aseptic conditions.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Batch production and control records do not include complete information relating to the production and control of each batch.
Laboratory controls do not include the establishment of scientifically sound and appropriate specifications and test procedures designed to assure that components and drug products conform to appropriate standards of identity, strength…
Laboratory records do not include complete data derived from all tests, examination and assay necessary to assure compliance with established specifications and standards.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports