FDA establishment 3003531601, Ann Arbor, Michigan, United States. Part of Michigan Medicine's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
21 CFR 211.167(a). Sterility/pyrogen-free testing Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.
21 CFR 211.94(c). Containers & Closures Clean, Sterilized, Pyrogen-free Drug product containers were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
21 CFR 211.42(c)(10)(v). Cleaning System Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
21 CFR 211.42(c)(10)(vi). Equipment to control conditions Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.28(a). Clothing appropriate for duties performed Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
21 CFR 211.192. Extent of discrepancy, failure investigations Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure or discrepancy.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 2 inspections, from the 483s FDA posted; newest first
Materials or supplies were not disinfected prior to entering the aseptic processing areas.
Personnel moved rapidly in the vicinity of instruments, which disrupted the airflow and increased the risk of bringing lesser quality air into the ISO 5 classified aseptic processing area.
Personnel engaged in aseptic processing were observed with exposed hands, exposed wrists, exposed legs, exposed hair and exposed mouth.
Your facility was designed and/or operated in a way that permits poor flow of materials.
The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate.
Investigations of a failure of a batch or any of its components to meet any of its specifications did not extend to other batches of the same drug product and other drug products that may have been associated with the specific failure orโฆ
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not written and followed.
Aseptic processing areas are deficient regarding systems for maintaining any equipment used to control the aseptic conditions.
Aseptic processing areas are deficient regarding the system for cleaning and disinfecting the equipment to produce aseptic conditions.
Clothing of personnel engaged in the processing of drug products is not appropriate for the duties they perform.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Each batch of drug product purporting to be sterile is not laboratory tested to determine conformance to such requirements.
Drug product containers were not sterilized and processed to remove pyrogenic properties to assure that they are suitable for their intended use.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports