FDA establishment 3002808145, Delhi, India. Part of Shriram Institute for Industrial Research's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 3
Official action indicated: 2
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.194(a)(2). Suitability of testing methods verified The suitability of all testing methods is not verified under actual conditions of use.
21 CFR 211.160(a). Following/documenting laboratory controls Established laboratory control mechanisms are not followed. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in current good manufacturing practices.
Official Action Indicated (OAI)
Oct 22, 2019
Drugs · Drug Quality Assurance
8 cited references
21 CFR 211.194(a)(3). Statement of Sample Weights and Measures Laboratory records are deficient in that they do not include a statement of the weight of the sample used for testing.
21 CFR 211.194(c). Testing and standardization of standards et. al. Laboratory records do not include complete records of any testing and standardization of laboratory reference standards, reagents and standard solutions.
21 CFR 211.194(a)(4). Data secured in course of each test Laboratory records do not include a complete record of all data secured in the course of each test, including all spectra from laboratory instrumentation, properly identified to show the specific component.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine inspection of electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.194(a)(2). Laboratory Test Method Verification Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use.
21 CFR 211.160(a). Following/documenting laboratory controls Established laboratory control mechanisms are not followed.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.194(a)(2). Reference and method not stated Laboratory records of methods of testing used do not indicate the method when employing methods in recognized standard references.
Official Action Indicated (OAI)
Aug 5, 2016
Drugs · Drug Quality Assurance
6 cited references
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine inspection of electronic equipment is not performed according to a written program designed to assure proper performance. Electronic records are used, but they do not meet requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.192. No written record of investigation Written records are not made of investigations into unexplained discrepancies.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate sampling plans designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.194(a)(2). Laboratory Test Method Verification Verification of the suitability of the testing methods is deficient in that they are not performed under actual conditions of use.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports