FDA establishment 3002759467, Pontoise, France. Part of Laboratoires Clarins's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 3
Official action indicated: 1
Warning letters: 2
Import refusals since 2014: 50
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.67(b). Written procedures fail to include Written procedures for cleaning and maintenance fail to include instructions for protection of clean equipment from contamination prior to use and parameters relevant to the operation.
Voluntary Action Indicated (VAI)
Sep 21, 2018
Drugs · Drug Quality Assurance
8 cited references
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.165(f). Failing drug products not rejected Drug products failing to meet established standards, specifications and quality control criteria are not rejected.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications do not always include the conclusions and follow-up.
21 CFR 211.67(b). Written procedures fail to include Written procedures for cleaning and maintenance fail to include instructions for protection of clean equipment from contamination prior to use and parameters relevant to the operation.
21 CFR 211.165(e). Test methods The accuracy, sensitivity, specificity and reproducibility of test methods have not been established and documented.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design, of adequate size and suitably located to facilitate operations for its intended use.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Official Action Indicated (OAI)
Nov 21, 2014
Drugs · Drug Quality Assurance
4 cited references
21 CFR 211.84(c)(4). Compositing of Sub Samples Components which must be sampled from top, middle and bottom of the container are not kept separate, but instead are composited for testing.
21 CFR 211.198(a). Reporting of adverse drug experience to FDA Written procedures describing the handling of all written and oral complaints do not include provisions for review to determine whether the complaint represents a serious and unexpected adverse drug experience which is required to be reported to the Food and Drug Administration.
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.22(c). Approve or reject procedures or specs The quality control unit lacks responsibility to approve and reject all procedures or specifications impacting on the identity, strength, quality, and purity of drug products.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports