FDA establishment 3002277609, Sejong, Korea (the Republic of). Part of Sinsin Pharmaceutical's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 5
Official action indicated: 0
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 0 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration and inspection of equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.42(b). Adequate space lacking to prevent mix-ups and contamination The building lacks adequate space for the orderly placement of equipment and materials to prevent mix-ups between in-process materials and drug products and to prevent contamination.
21 CFR 211.84(d)(1). Identity Testing of Each Component The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
21 CFR 211.160(b)(2). In-process sample representation/identification In-process samples are not representative.
21 CFR 211.166(a). Written program not followed The written stability testing program is not followed.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Voluntary Action Indicated (VAI)
Dec 13, 2019
Drugs · Drug Quality Assurance
4 cited references
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that components, in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned and sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not fully followed.
Voluntary Action Indicated (VAI)
Nov 24, 2017
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Mar 11, 2016
Drugs · Drug Quality Assurance
9 cited references
21 CFR 211.142. Written warehousing procedures established/followed Procedures describing the warehousing of drug products are not established.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel. Electronic records are used, but they do not meet system access limitation and systems documentation control requirements to ensure that they are trustworthy, reliable and generally equivalent to paper records.
21 CFR 211.194(a)(2). Suitability of testing methods verified The suitability of all testing methods is not verified under actual conditions of use.
21 CFR 211.84(c)(4). Compositing of Sub Samples Components which must be sampled from top, middle and bottom of the container are not kept separate, but instead are composited for testing.
21 CFR 211.110(c). In-process materials characteristics testing In-process materials are not tested for identity, strength, quality, and purity and approved or rejected by the quality control unit during the production process.
21 CFR 211.184(c). Individual inventory record Records fail to include an individual inventory record of each component and reconciliation of the use of each component with sufficient information to allow determination of any associated batch or lot of drug product.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans, and test procedures designed to assure that components, in-process materials, and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.80(b). Handling and Storage to Prevent Contamination There was a failure to handle and store components at all times in a manner to prevent contamination.
21 CFR 211.166(a)(3). Valid stability test methods The written stability program for drug products does not include reliable, meaningful, and specific test methods.
Voluntary Action Indicated (VAI)
Mar 2, 2012
Drugs · Drug Quality Assurance
5 cited references
21 CFR 211.110(a). Written in-process control procedures Written procedures are not established and followed that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which monitor the output and validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not sanitized at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.111. Establishment of time limitations Time limits are not established when appropriate for the completion of each production phase to assure the quality of the drug product.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports