FDA establishment 3001321832, Johor Bahru, Malaysia. Part of Luen Fook Medicine Sdn. Bhd.'s FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations, and the shipments FDA refused at the border.
Inspections: 2
Official action indicated: 1
Warning letters: 1
Import refusals since 2024: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.166(a)(3). Valid stability test methods The written stability program for drug products does not include meaningful and specific test methods.
21 CFR 211.160(b)(4). Calibration - at intervals, written program, remedial action The calibration of instruments is not done at suitable intervals in accordance with an established written program.
21 CFR 211.113(a). Procedures for non-sterile drug products Procedures designed to prevent objectionable microorganisms in drug products not required to be sterile are not established.
21 CFR 211.166(a). Lack of written stability program There is no written testing program designed to assess the stability characteristics of drug products.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, sampling plans and test procedures designed to assure that in-process materials and drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the identity and strength of each active ingredient prior to release.
21 CFR 211.170(b). Annual visual exams of drug products Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
Official Action Indicated (OAI)
May 22, 2015
Drugs · Drug Quality Assurance
11 cited references
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.67(b). Written procedures fail to include Written procedures for cleaning and maintenance fail to include description in sufficient detail of the methods of disassembling and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.204. Returned drug procedures in writing and followed Procedures describing the holding, testing, and reprocessing of returned drug products are not in writing.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.160(a). Following/documenting laboratory controls Established laboratory control mechanisms are not followed.
21 CFR 211.110(a). Written in-process control procedures Written procedures are not established that describe the in-process controls and examinations to be conducted on appropriate samples of in-process materials of each batch.
21 CFR 211.170(b). Annual visual exams of drug products Reserve samples from representative sample lots or batches of drug products selected by acceptable statistical procedures are not examined visually at least once a year for evidence of deterioration.
21 CFR 211.166(a)(3). Valid stability test methods The written stability program for drug products does not include meaningful and specific test methods.
21 CFR 211.80(a). Written Procedures Not Followed Written procedures are not followed for the identification of components.
21 CFR 211.101(a). Batches Formulated to less than 100% Written production and control procedures include batches formulated with the intent to provide less than 100 percent of the labeled or established amount of active ingredient.
21 CFR 211.166(a). Results not used for expiration dates, storage cond. Results of stability testing are not used in determining expiration dates.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports