FDA establishment 2919184, San Leandro, California, United States. Part of Columbia Cosmetics Manufacturing's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 6
Official action indicated: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.84(d)(2). Reports of Analysis (Components) Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate validation of the supplier's test results at appropriate intervals.
21 CFR 211.84(d)(1). Identity Testing of Each Component The identity of each component of a drug product is not verified by conducting at least one test to verify the identity, using specific identity tests if they exist.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy and the failure of a batch or any of its components to meet any of its specifications whether or not the batch has been already distributed.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.165(f). Failing drug products not rejected Drug products failing to meet established standards, specifications and quality control criteria are not rejected.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
Official Action Indicated (OAI)
Jan 29, 2020
Drugs · Drug Quality Assurance
5 cited references
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products and investigations conducted for each drug product.
21 CFR 211.165(f). Failing drug products not rejected Drug products failing to meet established standards, specifications and quality control criteria are not rejected.
21 CFR 211.67(b)(3). Cleaning SOPs/instructions Procedures for the cleaning and maintenance of equipment are deficient regarding sufficient detail of the methods, equipment, and materials used in the cleaning and maintenance operation, and the methods of disassembly and reassembling equipment as necessary to assure proper cleaning and maintenance.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate standards, sampling plans and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.192. No written record of investigation Written records are not made of investigations into unexplained discrepancies and the failure of a batch or any of its components to meet specifications.
Voluntary Action Indicated (VAI)
Jan 11, 2017
Drugs · Drug Quality Assurance
4 cited references
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine of automatic, mechanical and electronic equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards and test procedures designed to assure that conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
Voluntary Action Indicated (VAI)
Mar 27, 2015
Drugs · Drug Quality Assurance
15 cited references
21 CFR 211.22(a). Lack of quality control unit There is no quality control unit.
21 CFR 211.101(b). Identification of new containers For components removed from the original containers, the new container fails to be identified with weight or measure and batch for which component was dispensed including product name, strength and lot number.
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
21 CFR 211.84(d)(2). Testing Each Component for Conformity with Specs Each component is not tested for conformity with all appropriate written specifications for purity, strength, and quality.
FDCA 601(c). Insanitary conditions; contaminated with filth Your cosmetic was prepared, packed, or held under insanitary conditions whereby it may have become contaminated with filth.
21 CFR 211.198(a). Complaint Handling Procedure Procedures describing the handling of written and oral complaints related to drug products are deficiently written or followed.
21 CFR 211.160(b). Scientifically sound laboratory controls Laboratory controls do not include the establishment of scientifically sound and appropriate specifications, standards, and test procedures designed to assure that drug products conform to appropriate standards of identity, strength, quality and purity.
21 CFR 211.125(f). Procedures Written and Followed Procedures describing in sufficient detail the controls employed for the issuance of labeling are not followed.
21 CFR 211.100(a). Changes to Procedures Not Reviewed, Approved Changes to written procedures are not drafted, reviewed and approved by the appropriate organizational unit and reviewed and approved by the quality control unit.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not established and followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.25(a). Training , Education , Experience overall Employees engaged in the manufacture, processing, packing, and holding of a drug product lack the education, training, and experience required to perform their assigned functions.
21 CFR 211.110(a). Control procedures to monitor and validate performance Control procedures are not established which validate the performance of those manufacturing processes that may be responsible for causing variability in the characteristics of in-process material and the drug product.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration, inspection, and checking of equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.89. Quarantine of Rejected Components et. al. Rejected components are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Voluntary Action Indicated (VAI)
Nov 30, 2011
Drugs · Drug Quality Assurance
3 cited references
21 CFR 211.125(c). Label reconciliation discrepancies evaluation/investigation Discrepancies found outside preset limits when reconciling the quantities of labeling issued, used and returned, were not evaluated and investigated.
21 CFR 211.180(e). Records reviewed annually Records are not maintained so that data therein can be reviewed at least annually to evaluate the quality standards of each drug product to determine the need for changes in specifications or manufacturing or control procedures.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration of mechanical equipment is not performed according to a written program designed to assure proper performance.
Voluntary Action Indicated (VAI)
Dec 17, 2010
Drugs · Drug Quality Assurance
6 cited references
21 CFR 211.160(b)(4). Calibration - at intervals, written program, remedial action The calibration of recording devices is not done at suitable intervals in accordance with an established written program.
21 CFR 211.80(d). Identification of Each Lot in Each Shipment Each lot in each shipment received was not identified with a distinctive code for each container or grouping of containers for components.
21 CFR 211.188. Prepared for each batch, include complete information Batch production and control records do not include complete information relating to the production and control of each batch.
21 CFR 211.180(e)(2). Items to cover on annual reviews Written procedures are not followed for evaluations done at least annually and including provisions for a review of complaints, recalls, returned or salvaged drug products, and investigations conducted for each drug product.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine checking of mechanical equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.89. Quarantine of Rejected Components et. al. Rejected components are not controlled under a quarantine system designed to prevent their use in manufacturing or processing operations for which they are unsuitable.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports