FDA establishment 1650090, Houston, Texas, United States. Part of Bio-Medical Pharmaceutical Manufacturing's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 4
Official action indicated: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.165(a). Testing and release for distribution Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
21 CFR 211.63. Equipment Design, Size and Location Equipment used in the manufacture, processing, packing or holding of drug products is not of appropriate design to facilitate operations for its intended use.
21 CFR 211.142(b). Storage under appropriate conditions Drug products are not stored under appropriate conditions of temperature so that their identity, strength, quality, and purity are not affected.
21 CFR 211.84(c)(4). Top/Middle/Bottom container sampling Sampling procedures are deficient regarding sampling components from the top, middle, and bottom of container.
21 CFR 211.68(a). Calibration/Inspection/Checking not done Routine calibration and inspection of equipment is not performed according to a written program designed to assure proper performance.
21 CFR 211.67(a). Cleaning / Sanitizing / Maintenance Equipment and utensils are not cleaned and maintained at appropriate intervals to prevent contamination that would alter the safety, identity, strength, quality or purity of the drug product.
21 CFR 211.113(b). Procedures for sterile drug products Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not established.
21 CFR 211.188(b)(1). Significant Step Accomplishment Dates The batch production and control records are deficient in that they do not include dates of accomplished significant steps.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Official Action Indicated (OAI)
Jan 23, 2020
Drugs · Drug Quality Assurance
3 cited references
21 CFR 211.25(a). GMP Training Frequency GMP training is not conducted with sufficient frequency to assure that employees remain familiar with CGMP requirements applicable to them.
21 CFR 211.67(b). Written procedures not established/followed Written procedures are not followed for the cleaning and maintenance of equipment, including utensils, used in the manufacture, processing, packing or holding of a drug product.
21 CFR 211.68(a). Written calibration / inspection records not kept Records of the calibration checks of automatic, mechanical or electronic equipment, including computers or related systems are not maintained.
Voluntary Action Indicated (VAI)
Jan 14, 2016
Drugs · Drug Quality Assurance
None posted
No Action Indicated (NAI)
Jul 9, 2010
Drugs · Drug Quality Assurance
1 cited reference
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into the failure of a batch or any of its components to meet specifications do not include the conclusions and follow-up.
Voluntary Action Indicated (VAI)
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports