FDA establishment 1000251214, Otsu, Japan. Part of Toyobo's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations.
Inspections: 3
Official action indicated: 1
Form 483s posted: 1
Warning letters: 1
Inspections by fiscal year
FY2018 to FY2027 to date; 1 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
21 CFR 211.42(c)(10)(iv). Environmental Monitoring System Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
21 CFR 211.192. Written record of investigation incomplete Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
21 CFR 211.22(d). Procedures not in writing, fully followed The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
21 CFR 211.68(b). Computer control of master formula records Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
21 CFR 211.188(b)(4). Weights and measures of components used Batch production and control records do not include the weights and measures of components used in the course of processing each batch of drug product produced.
21 CFR 211.194(a). Complete test data included in records Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
21 CFR 211.100(b). SOPs not followed / documented Written production and process control procedures are not followed in the execution of production and process control functions.
21 CFR 211.194(a)(2). Suitability of testing methods verified The suitability of all testing methods is not verified under actual conditions of use.
21 CFR 211.192. Investigations of discrepancies, failures There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
21 CFR 211.28(b). Habits of good sanitation & health Production personnel were not practicing good sanitation and health habits.
21 CFR 211.25(a). Training--operations, GMPs, written procedures Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Official Action Indicated (OAI)
Jul 30, 2019
Drugs · Drug Quality Assurance
None posted
Voluntary Action Indicated (VAI)
Form 483 observations
What FDA investigators wrote up at the end of an inspection, from the 483s FDA posted; newest first
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
Aseptic processing areas are deficient regarding the system for monitoring environmental conditions.
Production personnel were not practicing good sanitation and health habits.
Laboratory records do not include complete data derived from all tests, examinations and assay necessary to assure compliance with established specifications and standards.
Written production and process control procedures are not followed in the execution of production and process control functions.
Written records of investigations into unexplained discrepancies do not include the conclusions and follow-up.
The suitability of all testing methods is not verified under actual conditions of use.
The responsibilities and procedures applicable to the quality control unit are not in writing and fully followed.
Batch production and control records do not include the weights and measures of components used in the course of processing each batch of drug product produced.
Appropriate controls are not exercised over computers or related systems to assure that changes in master production and control records or other records are instituted only by authorized personnel.
Employees are not given training in the particular operations they perform as part of their function and current good manufacturing practices.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports