FDA establishment 1000076625, Kennett Square, Pennsylvania, United States. Part of Boothwyn Pharmacy's FDA records. Every inspection FDA has posted for the site, with its outcome and cited regulations and its recalls since 2016.
Inspections: 3
Official action indicated: 3
Form 483s posted: 5
Warning letters: 1
Recalls since 2016: 2
Inspections by fiscal year
FY2018 to FY2027 to date; 2 classified OAI
How to read this
A hatched bar is a year that is not over, so its count covers only part of the year.
20182018Inspections0
20192019Inspections0vs 2018+0
20202020Inspections0vs 2019+0
20212021Inspections0vs 2020+0
20222022Inspections0vs 2021+0
120232023Inspections1vs 2022+1
20242024Inspections0vs 2023−1
120252025Inspections1vs 2024+1
20262026Inspections0vs 2025−1
20272027 to dateInspections0
Most Cited at This Site
Inspections citing each reference
FDCA 501(a)(2)(A): Sporicidal agent, ISO 5/classified areas1FDCA 501(a)(2)(A): Sporicidal agent, ISO 5/classified areasValue1
Inspections
3 inspections, newest first
Jun 9, 2025
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Aug 29, 2023
Drugs · Drug Quality Assurance
5 cited references
FDCA 501(a)(2)(A). Sporicidal agent, ISO 5/classified areas Use of a sporicidal agent in the facility's ISO 5 areas and classified areas was improper.
FDCA 501(a)(2)(A). Facility design, influx of lesser quality air The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air.
FDCA 501(a)(2)(A). Non-sterile disinfecting agents, ISO 5 area/classified areas Use of non-sterile cleaning wipes in the ISO 5 area.
FDCA 501(a)(2)(A). Beta-lactam, hazardous, highly potent drugs, prevention of cross-contamination Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination.
FDCA 501(a)(2)(A). Inadequate smoke studies Smoke studies were inadequately performed under dynamic conditions.
Official Action Indicated (OAI)
Jun 16, 2017
Drugs · Drug Quality Assurance
None posted
Official Action Indicated (OAI)
Form 483 observations
What FDA investigators wrote up at the end of 5 inspections, from the 483s FDA posted; newest first, the 4 newest
Your firm released drug product in which the strength differs from, or its purity or quality falls below, that which it purports or is represented to possess.
Drug held under environmental conditions whereby it may have been rendered injurious to health.
Sterile drugs and materials were exposed to lower than ISO 5 quality air.
Personnel were observed conducting aseptic manipulations where the movement of "first air" in the ISO 5 area is blocked or disrupted.
Smoke Studies were inadequately performed under dynamic conditions.
Production areas have difficult to clean or contain porous, particle generating, or visibly dirty equipment or surfaces.
Testing and release of drug product for distribution do not include appropriate laboratory determination of satisfactory conformance to the final specifications prior to release.
Procedures designed to prevent microbiological contamination of drug products purporting to be sterile are not followed.
There is a failure to thoroughly review any unexplained discrepancy whether or not the batch has been already distributed.
The quality control unit lacks the responsibility and authority to approve all components and drug products.
Reports of analysis from component suppliers are accepted in lieu of testing each component for conformity with all appropriate written specifications, without establishing the reliability of the supplier's analyses through appropriate…
Smoke studies were inadequately performed under dynamic conditions.
The facility design was observed to allow the influx of lesser quality air into a classified area containing higher quality air.
Use of non-sterile cleaning wipes in the ISO 5 area.
Hazardous drugs were produced without providing adequate containment, segregation, and/or cleaning of work surfaces, utensils, and/or personnel to prevent cross-contamination.
Personnel conducted aseptic manipulations and placed equipment/supplies in an area that blocked the movement of first pass air around an open unit, either before or after it was filled with sterile product.
You produced hazardous drugs without providing adequate containment, segregation, cleaning of work surfaces, cleaning of utensils and cleaning of personnel to prevent cross-contamination.
Equipment was and Materials or supplies were not disinfected prior to entering the aseptic processing areas.
The use of sporicidal agents in the cleanrooms and ISO 5 classified aseptic processing area was inadequate.
The ISO 5 classified aseptic processing areas had difficult to clean, particle-generating and visibly dirty equipment or surface.
Personnel sampling was conducted after gloves had been cleaned/disinfected.
Your media fills were not performed under the most challenging or stressful conditions.
ISO-5 classified areas were not certified under dynamic conditions.
Your facility failed to confirm that the quality of water was suitable for its intended use in the production of non-sterile drug products.
Warning letters
Letters naming this establishment; each opens the letter
An FEI (FDA Establishment Identifier) names one physical site. Inspections, outcomes and citations come from FDA's Data Dashboard; FDA posts citations only for some inspections. Recalls come from FDA's enforcement reports (iRES), one row per recall even when it covers many lots. A contract site can make products for many companies, so the company shown is the one FDA lists as the site's firm. Form 483 observations are read by Arca from the 483s FDA posts in its FOIA reading room, most of them scans: the first sentence of each observation, with redactions as FDA made them. FDA posts 483s for a minority of inspections.FDA Data Dashboard, warning letters and enforcement reports