Arca
Skip to content
Tools
Tools

Topical Dermatologic Corticosteroids: In Vivo Bioequivalence

US Food and Drug Administration CDER, final guidance. In the week of Jul 13 to 19, 2026.

  • Issued: Jul 14, 2026

Summary

Each point with the passage it rests on

What it says

  1. Applicants submitting ANDAs for topical dermatologic corticosteroids should conduct a pilot dose duration vasoconstrictor response study using the reference standard, followed by a pivotal vasoconstrictor BE study comparing the test product and reference standard.

    this guidance recommends that ANDA applicants that propose to use an in vivo pharmacodynamic approach to demonstrate BE between a test topical corticosteroid and its RS conduct two in vivo vasoconstrictor studies: (1) a pilot dose duration vasoconstrictor response stud y, using the RS; and (2) a pivotal vasoconstrictor BE study, comparing the test topical corticosteroid and RS.
  2. For the pivotal study, the 90 percent confidence interval for the test-to-reference AUEC ratio should fall within 80.00 to 125.00 percent, calculated from detectors' data using Locke's method.

    The 90 percent confidence interval for the test to reference AUEC ratio should be within the 80.00 to 125.00 percent interval.
  3. Chromameter and operator qualifications should show variability (percent CV) of not more than 15 percent in each and every subject before a study starts.

    the variability (percent coefficient of variation (CV)) for the intrachromameter and the interchromameter measurements should be not more than 15 percent in each and every subject.

What changed

  1. This guidance replaces the guidance for industry on Topical Dermatologic Corticosteroids: In Vivo Bioequivalence that was issued in June 1995.

    This guidance replaces the guidance for industry Topical Dermatologic Corticosteroids: In Vivo Bioequivalence that was issued in June 1995.

Who should care

  1. The guidance is intended for ANDA applicants seeking approval of generic topical dermatologic corticosteroid products of all potencies, and it should be read by those in the generic drug industry.

    This guidance is intended to assist applicants that submit abbreviated new drug applications (ANDAs) for topical dermatologic corticosteroid products of all potencies

Sources

From FDA and the Federal Register

Record

Agency
US Food and Drug Administration CDER
Type
Guidance
Status
Final
Issued
Jul 14, 2026

Status, dates, docket and comment deadline are read from FDA's own records and the docket's notice on Regulations.gov or in the Federal Register. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.