Submitting Clinical Trial Datasets to Evaluate the Impact of Immunogenicity on the Pharmacokinetics of a Drug
US Food and Drug Administration CDER, final guidance. In the week of Jun 15 to 21, 2026.
- Issued: Jun 18, 2026
What it says
The guidance gives detailed data specifications for three datasets for submission: the Analysis Dataset for Immunogenicity Specimen (ADIS), the Analysis Dataset for Pharmacokinetic Concentrations (ADPC), and the Subject-Level Analysis Dataset (ADSL).
This document provides detailed data specifications for the following datasets:
Each immunogenicity specimen should have a final ADA status, reported as "ADA conclusion", based on the results from "ADA screening" and "ADA confirmatory" tests.
Each immunogenicity specimen (sample) should have a final ADA status based on the results from “ADA screening” and “ADA confirmatory” tests.
The ADA conclusion should be reported as "negative" or "positive" when the assay has adequate drug tolerance, and as "inconclusive" when drug tolerance is not adequate.
The output of “ADA conclusion,” AVALC, should take only a definitive value in floating text of either “negative” or “positive” when the assay has an adequate drug tolerance relative to the drug concentration.
Sponsors should also submit the programs used to create these datasets, and variables that are omitted or added should be documented in the Define.xml file and itemized in the Analysis Data Reviewer Guide.
Sponsors should also submit programs that were used to create these datasets
Time variables such as AVISIT and ATPT should be coded consistently across ADIS and ADPC so that time-matched immunogenicity and pharmacokinetic measures can be merged.
to allow for proper mapping of time-matched pharmacokinetics and IS rows, the time variables presented in both ADIS and ADPC (e.g., AVISIT) should be coded consistently.
- Agency
- US Food and Drug Administration CDER
- Type
- Guidance
- Status
- Final
- Issued
- Jun 18, 2026
- Docket
- FDA-2017-D-6821
Status, dates, docket and comment deadline are read from FDA's own records and the docket's notice on Regulations.gov or in the Federal Register. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.