Arca
Skip to content
Tools
Tools

Reflection paper on the qualification of non-mutagenic impurities

European Medicines Agency CHMP, final scientific guideline. In the week of Feb 2 to 8, 2026.

  • Issued: Feb 2, 2026
  • Comments closed: Apr 30, 2025

Summary

Each point with the passage it rests on

What it says

  1. Additional in vivo qualification studies are only to be considered when alternative methods fail to establish the safety of an impurity at the proposed specification limit, with appropriate scientific justification.

    Only when alternative methods fail to provide sufficient information to establish the safety of an impurity at the proposed specification limit, and with appropriate scientific justification, should in vivo studies be considered.
  2. An acceptable level (AL) for an impurity is derived from a point of departure, such as a BMDL or NOAEL, with assessment factors applied to account for species, variability, study duration, severity, and route differences.

    Subsequently, AFs are applied for inter- and intraspecies variability (AF1 and AF2, respectively), duration of the study from which the PoD is taken (AF3), severity of the toxicity (AF4) and the absence of a BMDL or NOAEL (AF5).
  3. A daily impurity exposure of 1 mg/day is treated as a reference point rather than a definitive cut-off, and exposure above it increases the level of concern.

    EMA does not regard the 1 mg/day threshold as a definitive cut-off value. Instead, it is treated as a reference point - the midpoint on the daily dose scale illustrated in Figure 2.

Sources

From EMA

Record

Agency
European Medicines Agency CHMP
Type
Scientific guideline
Status
Final
Issued
Feb 2, 2026
Page last changed
Mar 13, 2026
Reference
EMA/CHMP/4299/2026 CORR.

Status, dates, docket and comment deadline are read from EMA's own records. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.