Protein Efficiency Ratio (PER) Rat Bioassay Studies to Demonstrate that a New Infant Formula Supports the Quality Factor of Sufficient Biological Quality of Protein
US Food and Drug Administration HFP, final guidance. In the week of May 18 to 24, 2026.
- Issued: May 21, 2026
What it says
The PER rat bioassay must be conducted on a formula and its results evaluated before starting the growth monitoring study of that formula required under 21 CFR 106.96(b).
The PER rat bioassay shall be conducted on a formula and the results evaluated prior to the initiation of a growth monitoring study of the formula that is required under 21 CFR 106.96(b).
The casein reference diet should be matched to the infant formula test diet, with nutrients such as minerals and vitamins matched to within 20% of the test diet levels.
We recommend the matching of nutrients in casein reference diets, including minerals and vitamins, to within 20% of the corresponding levels in the test diets.
Liquid infant formulas must be freeze dried so the test sample contains more than 1.8% nitrogen before the infant formula test diet is formulated.
Liquid infant formulas must be freeze dried so that the test sample contains more than 1.8% nitrogen before the infant formula test diet is formulated.
The casein reference diet must contain a level of lactose comparable to the amount in the infant formula test diet.
The casein reference control diet(s) must contain levels of lactose comparable to the amount in the infant formula test diet to adjust for possible confounding of the estimation of protein quality.
Who should care
The guidance is intended to help manufacturers and laboratories in the design, conduct, evaluation, and reporting of PER studies for infant formula.
We have developed this guidance to help manufacturers and laboratories in the design, conduct, evaluation, and reporting of PER studies.
- Agency
- US Food and Drug Administration HFP
- Type
- Guidance
- Status
- Final
- Issued
- May 21, 2026
- Docket
- FDA-2022-D-2424
Status, dates, docket and comment deadline are read from FDA's own records and the docket's notice on Regulations.gov or in the Federal Register. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.