Arca
Skip to content
Tools
Tools

ICH Q1 EWG Stability Testing of Drug Substances and Drug Products: Q1 Guideline

International Council for Harmonisation, final guideline. In the week of Nov 16 to 22, 2026.

  • Issued: Nov 17, 2026

Summary

Each point with the passage it rests on

What it says

  1. ICH Q1 is a consolidated revision that supersedes the ICH Q1A–F and ICH Q5C guidelines and provides additional guidance on principles relating to stability.

    ICH Q1 is a consolidated revision that supersedes the ICH Q1A–F and ICH Q5C guidelines and provides additional guidance on principles relating to stability.
  2. For new synthetic chemical entities, data from 12 months of long-term and 6 months of accelerated stability studies from 3 primary batches should be provided to support the proposed re-test period or shelf life.

    For new synthetic chemical entity drug substances and/or drug products for which a new drug regulatory submission is necessary, data from 12 months of long-term and 6 months of accelerated stability studies from 3 primary batches should be provided to support the proposed re-test period or shelf life.
  3. For testing frequency at long-term storage, a product with a proposed shelf life of less than 12 months should be tested monthly for the first 3 months and at 3-month intervals thereafter.

    For a drug substance or drug product with a proposed re-test period/shelf life of less than 12 months, the frequency of testing at the long-term storage condition is recommended monthly for the first 3 months and at 3-month intervals thereafter.
  4. Ongoing stability studies should add at least one production batch of the drug substance and one production batch of each strength of the drug product per year, unless none is produced that year.

    at least one production batch of the drug substance and one production batch of each strength of the drug product covering the container closure systems (refer to Section 5 – Container Closure System) should be added to the ongoing stability programme per year, unless none is produced that year.
  5. Confirmatory photostability studies should provide a total light exposure of not less than 1.2 million lux hours and an integrated near UV energy of not less than 200 Wh/m2.

    samples should be exposed to light providing a total light exposure of not less than 1.2 million lux hours and an integrated near UV energy of not less than 200 Wh/m2.

Who should care

  1. The guideline applies to regulatory submissions for synthetic and biological drug substances and drug products, including vaccines, cell-based products, and drug-device combinations, and it is relevant to those working on stability in the life sciences industry.

    This guideline applies to synthetic and biological drug substances and drug products, including the following:

Sources

From ICH

Record

Agency
International Council for Harmonisation
Type
Guideline
Status
Final
Issued
Nov 17, 2026
Reference
Q1 EWG

Status, dates, docket and comment deadline are read from ICH's own records. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.

Esc

Type a name: a tool, a company, a drug or brand, a condition, a gene or a state. Identifiers like K231234, NCT05012345 or NDA 215866 open their record.