E14 and S7B Clinical and Nonclinical Evaluation of QT/QTc Interval Prolongation and Proarrhythmic Potential--Questions and Answers (R1): Guidance for Industry
US Food and Drug Administration CDER, CBER, final guidance. In the week of Oct 26 to Nov 1, 2026.
- Issued: Oct 30, 2026
What it says
For a negative thorough QT/QTc study, the ICH E14 criteria define a negative study as an upper one-sided 95 percent CI of QTc prolongation effect less than 10 ms.
A negative study as defined by the ICH E14 criteria is an upper one-sided 95 percent CI of QTc prolongation effect less than 10 ms.
When concentration-response analysis is the primary basis for classifying a drug's risk, the upper bound of the two-sided 90 percent CI for the QTc effect at the highest clinically relevant exposure should be less than 10 ms to conclude that expanded ECG evaluation in later stages is not needed.
the upper bound of the two-sided 90 percent CI for the QTc effect of a drug treatment as estimated by exposure-response analysis should be less than 10 ms at the highest clinically relevant exposure to conclude that an expanded ECG safety evaluation during later stages of drug development is not needed.
Bazett's correction is described as an inferior method, so QT data corrected with Bazett's are no longer warranted in all applications unless there is a compelling reason, and Fridericia's correction is likely appropriate in most situations.
In adults, Bazett’s correction has been clearly shown to be an inferior method of correcting for differences in heart rate among and within subjects. Therefore, QT interval data corrected using Bazett’s corrections is no longer warranted in all applications unless there is a compelling reason for a comparison to historical Bazett’s corrected QT data.
Under the integrated nonclinical and clinical risk assessment, a drug with low likelihood of proarrhythmic effects due to delayed repolarization needs nonclinical data showing low risk, high-quality ECG data not suggesting QT prolongation, and a cardiovascular safety database that does not suggest increased rate of proarrhythmic adverse events.
A drug that meets the following criteria would be considered to have a low likelihood of proarrhythmic effects due to delayed repolarization:
Who should care
Sponsors developing drugs, including small molecules and biologics, and the reviewers of their QT/QTc and proarrhythmic evaluations should read this guidance, which is for industry.
Guidance for Industry
- Agency
- US Food and Drug Administration CDER, CBER
- Type
- Guidance
- Status
- Final
- Issued
- Oct 30, 2026
- Docket
- FDA-2020-D-1791
Status, dates, docket and comment deadline are read from FDA's own records and the docket's notice on Regulations.gov or in the Federal Register. The summary is written by a language model and checked by matching each quoted passage against the document; it is a reading aid, not the document.