YXLON Cougar Cabinet X-Ray System Product Usage: The products are generally used for…
Recall Z-2106-2019, part of FDA recall event 83295. See Comet Technologies USA's company page.
Comet Technologies Usa Inc started this Class II device recall on Oct 1, 2018 (fda mandated); FDA lists it as terminated, terminated Jun 13, 2024.
- Classification: Class II
- Started: Oct 1, 2018
- Status: Terminated
- Products in this event: 2
Failure to meet the requirement of the performance standard for cabinet x-ray systems (21 CFR 1020.40) for a door interlock that causes physical disconnection of the power supply using only the movement of the door.
- Product
- YXLON Cougar Cabinet X-Ray System Product Usage: The products are generally used for non-destructive testing and quality control
- Quantity
- 93
- Lots and codes
- X-Ray Systems
- Distribution
- US Nationwide Distribution
- Recalling firm
- Comet Technologies Usa Inc, Shelton, CT, United States
- How the firm notified
- Letter
- FDA classified
- Aug 7, 2019
- YXLON Cheetah cabinet X-Ray System Product Usage: The products are generally used for non-destructive testing and…Z-2105-2019 · Class II · Oct 1, 2018 · Terminated
FDA's weekly Enforcement Report, as openFDA publishes it. A recall is classified by how likely the product is to cause harm: Class I is the most serious. openFDA device enforcement reports