OLR: Oral Wound Dressing
FDA product code OLR. Unclassified. What the classification flags say about Part 820 under the QMSR.
As of Nov 9, 2026, FDA product code OLR (Oral Wound Dressing) is Unclassified, reviewed through 510(k), with 43 linked 510(k), De Novo or BK numbers, 0 PMAs and 1 recall product record.
Classification
- Product code
- OLR
- Device name
- Oral Wound Dressing
- Device class
- Unclassified (reason: pre-amendment)
- Regulation
- FDA lists no classification regulation for this code
- Review panel
- Dental
- Premarket route
- 510(k)
- CGMP-exempt flag
- No
- Life-sustaining flag
- No
- Implant flag
- No
- Third-party review
- Not a candidate
- Summary malfunction reporting
- Eligible
FDA definition. Intended as a physical barrier for temporary protection of oral mucosal tissue and to provide pain relief. Unclassified status per SE to MGQ.
Data from openFDA as of Nov 9, 2026. Read the record on openFDA · FDA product code classification database
Part 820 requirements the flags point to
Part 820 rules for OLR
- CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
- Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
- Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
- Database cannot sayFDA lists this code as unclassified.820.10(c) names class I, II and III devices. The database holds none of those for this code, so it cannot say whether clause 7.3 applies.21 CFR 820.10
- Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
- Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
- Complaint and record content21 CFR 820.35
- Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions
These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.
Clearances and recalls on record
- 510(k), De Novo and BK numbers linked
- 43 · Search these clearances
- PMA numbers linked
- 0
- Recall product records
- 1
- Adverse event reports
- Search MAUDE for OLR
Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.
Newest OLR clearances
- NaturaJel™ Oral Wound Care Kit: HCS Innovation, LLC, Aug 5, 2026
- Emanate Tray: Emanate Biomedical, Jul 29, 2026
- Curajel™ Oral Gel: USpharma, Ltd., Jun 15, 2026
- MuCover (proposed name) Oral Wound Dressing: MoleculeX Co., Ltd., May 21, 2026
- Dental Cone; Dental Sponge: Medizin Produkte Neustadt GmbH (Mpn), Dec 18, 2025
- Silatrix Oral Gel: Sa3, LLC, Oct 23, 2025
- Elemental Granulate: Zinkh NV, Jan 3, 2025
- HealiAid Dental Collagen Wound Dressing: Maxigen Biotech, Inc., Nov 22, 2023
- PerioStom Dental Dressing: Forward Science, LLC, Dec 22, 2022
- Ora-Aid: Tbm Corporation, Jan 11, 2022
Search all 7,103 product codes, or read the guide to the Part 820 rules behind these flags.