KNG: Monitor, Ultrasonic, Fetal
FDA product code KNG. Class II, classified under 21 CFR 884.2660. What the classification flags say about Part 820 under the QMSR.
As of Nov 9, 2026, FDA product code KNG (Monitor, Ultrasonic, Fetal) is Class II under 21 CFR 884.2660, reviewed through 510(k), with 60 linked 510(k), De Novo or BK numbers, 0 PMAs and 1 recall product record.
Classification
- Product code
- KNG
- Device name
- Monitor, Ultrasonic, Fetal
- Device class
- Class II
- Regulation
- 21 CFR 884.2660
- Review panel
- Obstetrics/Gynecology
- Premarket route
- 510(k)
- CGMP-exempt flag
- No
- Life-sustaining flag
- No
- Implant flag
- No
- Third-party review
- Candidate for third-party review
- Summary malfunction reporting
- Ineligible
Data from openFDA as of Nov 9, 2026. Read the record on openFDA · FDA product code classification database
Part 820 requirements the flags point to
Part 820 rules for KNG
- CGMP exemptionClassification regulation, 21 CFR parts 862 to 892
- Not flaggedFDA does not flag this product code as exempt.A manufacturer of a finished device of this type falls under part 820 (21 CFR 820.1(a)). Some classification regulations exempt only part of a generic device type, so read the regulation for your device.FDA: QMSR, CGMP exemptions · 21 CFR 820.35
- Design and development, ISO 13485 clause 7.321 CFR 820.10(c)
- Rule names this classRule names Class II.21 CFR 820.10(c) requires manufacturers of class II and class III devices to comply with clause 7.3 and its subclauses.21 CFR 820.10
- Traceability, ISO 13485 clause 7.5.9.221 CFR 820.10(d)
- Not flaggedFDA does not flag this code as life-supporting or life-sustaining.820.10(d) is not indicated by this flag.21 CFR 820.10 · 21 CFR 860.3 · QMSR final rule, comment 49
- Complaint and record content21 CFR 820.35
- Rule names this classApplies to every finished-device manufacturer, exempt or not.820.35 adds content to complaint records, servicing records and UDI recording on top of ISO 13485 clause 4.2.5. FDA says CGMP exemption does not lift these records.21 CFR 820.35 · FDA: QMSR, CGMP exemptions
These flags describe the classification of a product code. They are not a determination for a specific device or manufacturer. How a manufacturer meets 21 CFR 820.10 depends on its own device, its intended use and the full text of the rule.
Clearances and recalls on record
- 510(k), De Novo and BK numbers linked
- 60 · Search these clearances
- PMA numbers linked
- 0
- Recall product records
- 1
- Adverse event reports
- Search MAUDE for KNG
Recall records count products, and one recall event can add many. Counts show activity in a category. They do not measure its safety.
Newest KNG clearances
- Fetal Doppler U8-25, U9-25: Zhongshan Xiaolan Town Senlan Electronic Factory, Jan 8, 2026
- Doppler FHR Detector (BF-500D+, BF-560): Shenzhen Bestman Instrument Co., Ltd., Jun 26, 2025
- Ultrasonic Fetal Doppler: Shenzhen Jamr Technology Co., Ltd., Jun 28, 2024
- Pocket Fetal Doppler (CONTEC 10D), Pocket Fetal Doppler (CONTEC 10E), Pocket…: Contec Medical Systems Co.,Ltd, Jun 14, 2024
- Pocket Fetal Doppler (Models CONTEC10C and CONTEC10CL): Contec Medical Systems Co.,Ltd, Sep 28, 2022
- Fetal Doppler: Shenzhen Taikang Medical Equipment Co., Ltd., Jan 7, 2022
- Fetal Doppler: Shenzhen Mericonn Technology Co., Ltd., Nov 3, 2021
Search all 7,103 product codes, or read the guide to the Part 820 rules behind these flags.
Check your quality documents against Part 820
Arca puts your SOPs and design files in a library and compares them against the Part 820 requirements for your device in a grid, one row per document and one column per requirement, with each cell cited to its source.