FDA Review and Meeting Minutes Search
Before approving a drug, FDA's scientists write long reviews of the evidence, and its meetings with the company along the way are minuted. FDA publishes both after approval; this searches their full text.
Search what FDA's reviewers wrote about novel drugs and biologics, most approved since 2015: the clinical, statistical, pharmacology/toxicology and clinical pharmacology reviews in each Drugs@FDA approval package, and the minutes of the sponsor's meetings with FDA filed with them. Each result opens FDA's PDF at the page.
- Approval packages: 797
- Documents with text: 4,585
- Searchable pages: 335,761
- Meeting minutes pages: 19,263
- Statistical reviewStatistical review, page 21
upper bound of the 90% confidence interval of the risk difference is 8.36%, which is below the pre-specified non-inferiority margin of 10%. Proportion with positive ADA Proportion with positive NAb Reference ID: 4271724 Table 3 Results (FAS) PF-06881893 US-licensed Neupogen
1 more matching page in this file
- Statistical reviewMulti-discipline review, page 104
lower limit of the two-sided 95% CI for the difference in the ITT population was not greater than the non-inferiority margin of 10%. For ABSI-1108, the planned sample size of 632 patients was based on the response rate assumption
1 more matching page in this file
- Statistical reviewStatistical review, page 29
roughly similar between revefenecin 175 mcg and tiotropium, although the trial was not designed to establish similarity (there was no planned non-inferiority margin and hypothesis test). According to the applicant, the increased observed trough FEV1 profile on Day 365 in the tiotropium
- Statistical reviewStatistical review, page 21
acting rh-G-CSF Neulasta®, a single dose of pegfilgrastim (Neulasta®) was compared to daily administrations of filgrastim (Neupogen®) with a non-inferiority margin of -1 day for the duration of Grade 4 neutropenia in breast cancer patients treated with myelosuppressive chemotherapy. This limit
1 more matching page in this file
- Statistical reviewStatistical review, page 25
Table 9) because the upper limits of the 95% CIs for differences (LY900014-Humalog) were less than the pre-specified non-inferiority margin of 0.4% and of 0.3% in both trials. The difference in treatment effect of post meal insulin and Humalog
1 more matching page in this file
fosnetupitant chloride hydrochloride; palonosetron hydrochloride
Helsinn HealthcareNDA 210493 · approved Apr 19, 2018
Statistical reviewMulti-discipline review, page 294method for difference in proportions, stratified by gender and country according to Koch et al. and O’Gorman et al. The non-inferiority margin is set to 15%. P-value associated with non-inferiority testing. Table 7 Statistical Reviewer’s Age Subgroup Analysis Results
- Statistical reviewMulti-discipline review, page 108
protocols specified using a one-VLGHG WKH Į &0+ =-test adjusted by investigator site (pooled). The protocols specified using a non-inferiority margin of 10%, i.e., the lower bound of the 2-sided 95% confidence interval for the difference (guselkumab minus adalimumab) in proportions would
- Statistical reviewMulti-discipline review, page 95
make the assessment of clinical response is appropriate since this may reduce investigator biases. The pre-specified non-inferiority margins of 10% (Trial 008) and 12.5% (Trial 025) are also appropriate since both margins are smaller than the estimated effect size of antibacterial therapy
2 more matching pages in this file
- Statistical reviewStatistical review, page 47
bone marrow recovery (CRi), and partial response (PR). The sample size for part 2 was based on Ctrough levels of rituximab. Non-inferiority margin 0.8 was used with 63% coefficient of variation for a power of 80% and type I error of 5%. The sample
- Statistical reviewStatistical review, page 8
𝑣𝑠. 𝐻15: 𝜇25𝑚𝑔 > 𝜇𝑒𝑛𝑡 ‒ 𝛿 ; 𝐻06: 𝜇50𝑚𝑔 = 𝜇𝑒𝑛𝑡 ‒ 𝛿 𝑣𝑠. 𝐻16: 𝜇50𝑚𝑔 > 𝜇𝑒𝑛𝑡 ‒ 𝛿 , where δ denotes the shift parameter or non-inferiority margin for mean reduction in OFF-time and was set to δ = 30 minutes. The non-inferiority tests were done
- Statistical reviewStatistical review, page 10
controlled, 26-week, multi-center studies. The objective of studies EFC 12619 (6-month) and EFC 13403 were to demonstrate noninferiority (non-inferiority margin of 0.3%) of SAR342434 versus Humalog in patients with type 1 and type 2 diabetes, respectively, with respect to change
1 more matching page in this file
- Statistical reviewStatistical review, page 14
study was 394 patients in the mMITT population. This was expected to provide at least 85% power using a non-inferiority margin of -15% at one-sided α level of 0.025, assuming a response rate for the co-primary endpoints in both treatment groups being
- Statistical reviewMulti-discipline review, page 54
XVWHNLQXPDE WUHDWPHQW HIIHFW IURP WKH PHWD-analysis. The upper margin of 10 non-superiority was chosen to be symmetric to the non-inferiority margin. Sample Size Calculation The sample size of 542 was calculated based on equivalence at a significance level
- Statistical reviewStatistical review, page 16
family-wise 2-sided type 1 error rate of α=0.05 across the ranked endpoints and comparisons. The applicant specified a non-inferiority margin of 10% using ACR50 comparing upadacitinib and adalimumab. It is unclear from the protocol the objective of this comparison in presence
1 more matching page in this file
ceftobiprole medocaril sodium
Basilea Pharmaceutica International, Ltd., AllschwilNDA 218275 · approved Apr 3, 2024
Statistical reviewIntegrated review, page 69overall success of 40% in each treatment arm in the mITT population One-sided alpha level of 0.025 Power of >80% Non-inferiority margin of 15% for the between-arm difference in the primary endpoint With these assumptions, enrollment of 175 subjects per treatment
1 more matching page in this file
- Statistical reviewStatistical review, page 6
mean change from baseline in ETDRS BCVA score at the Week 8 visit in comparison to ranibizumab group using a non-inferiority margin of -3.5 letters. Therefore, there is no sufficient efficacy evidence to demonstrate bevacizumab 1.25 mg is noninferior to ranibizumab
1 more matching page in this file
- Statistical reviewStatistical review, page 105
controlled key efficacy trials, testing of non-inferiority for change in HbA1c was performed before testing for superiority. The pre-specified non-inferiority margin was 0.3%. For the key efficacy trials with two semaglutide doses, semaglutide 1.0 mg was tested before semaglutide 0.5 mg within
1 more matching page in this file
- Statistical reviewMulti-discipline review, page 121
submitted clinical data from MMY3012 show that daratumumab SC was non-inferior to daratumumab IV based on the protocol pre-specified non-inferiority margin. The submitted clinical data from MMY2040 show that the two cohorts (D-VMP and D-Rd), for which the Applicant requested
- Statistical reviewStatistical review, page 16
limit of the 95% confidence interval for the treatment difference (Vyzulta -Timolol) at that particular time point is less than the non-inferiority margin of 1.5 mmHg, and superior (yes) means that the upper limit of the 95% confidence interval for the 15 Reference
1 more matching page in this file
- Statistical reviewStatistical review, page 6
significantly different from placebo, the non-inferiority of gepirone ER cannot be determined due to the lack of non-inferiority margin. And it cannot be determined if the advantage of gepirone ER in not increasing sexual dysfunction related AE was consistently over the studies because
FDA's review PDFs for approvals from Jan 4, 1972 to Sep 25, 2026, read page by page from their text layer and refreshed weekly. Scanned pages without text are not searched. Drugs@FDA approval packages
About this search
What is searched
Every review file in the approval package: the clinical (medical) review; the statistical review; the nonclinical (pharmacology/toxicology) review; the clinical pharmacology review; the summary, cross-discipline team leader and office director reviews, and since 2019 the integrated or multi-discipline review that combines them; and product quality, microbiology, risk management, other reviews and the administrative and correspondence file. Approval letters, labels and proprietary name reviews are left out.
Pages in the correspondence files that are FDA's minutes of a meeting with the sponsor, from the “Memorandum of Meeting Minutes” heading to the electronic signature page, are marked as meeting minutes and labelled with the meeting (pre-IND, end of phase 2, pre-NDA, pre-BLA or the meeting type).
How to search
Words are matched in any form (dose, doses, dosing). Put a phrase in quotes to match it exactly, write or between alternatives (“carcinogenicity or carcinogenic”), and put a minus before a word to leave out pages that use it.
Frequently asked questions
- Where are the meeting minutes from?
- FDA does not publish meeting minutes on their own. When it posts an approval package on Drugs@FDA, the Administrative and Correspondence Documents (and sometimes Other Reviews) file often includes FDA's minutes of the sponsor's pre-IND, end-of-phase-2, pre-NDA or pre-BLA meetings, with FDA's written answers to the sponsor's questions. This search marks those pages as meeting minutes.
- Which approvals are covered?
- Novel drugs (NDAs for new molecular entities, chemical type 1) and original BLAs whose approval package FDA has posted, most approved since 2015 with some older packages. Supplements, generics and other new NDAs are not included yet.
- Why is a document I expect missing?
- FDA posts packages months after approval and redacts parts of them. Some older packages are scanned images with no text layer; those pages cannot be searched until they are read with OCR, which this search does not do yet.
- How are results ranked?
- By Postgres full-text relevance: how often and how close together the search words appear on a page. Each document shows its best-matching page, with the number of other matching pages.