Neurotherm RF Cannula
Probe, Radiofrequency Lesion. 510(k) K994344, from Rocket Medical Plc (Washington, Tyne & Wear, GB). Product code GXI, class 2.
As of Nov 19, 2026, K994344 is an FDA 510(k) held by Rocket Medical Plc, substantially equivalent on Mar 21, 2000 after 90 days, with no recalls tied to it in FDA's recall database.
- Review time: 90 days
- Recalls: 0
- Cited as a predicate by: 3 devices
The Neurotherm Radiofrequency Lesion cannula is indicated for use in neurosurgical lesioning procedures. Examples of these procedures include, but are not limited to, lesioning of nerve fibers for the treatment of pain and lesioning of the brain, spinal cord as in thalamotomies, pallidotomies, cordotomies and hypophysectomies.
- Owl CannulaeK102566 · Diros Technology, Inc. · Jun 3, 2011
- Intracept Bi-Polar RF Probe, Model 04814K070443 · Relievant Medsystems, Inc. · Oct 5, 2007
- Cosman Csk RF Cannula; Cosman Rfk RF CannulaK060799 · Cosman Medical, Inc. · May 2, 2006
- Disposable Radiofrequency CannulaK253907 · Abbott Medical · Apr 16, 2026
- STAR RF Ablation SystemK251802 · Merit Medical Systems, Inc. · Feb 13, 2026
- OneRF Trigeminal Nerve Radiofrequency ProbesK251243 · Neuroone Medical Technologies Corp. · Aug 15, 2025
- Disposable RF Electrode (RFDE-5/RFDE-10/RFDE-15/RFDE-20)K242841 · Abbott Medical · May 27, 2025
- OptaBlate BVN Intraosseous Nerve Ablation System (10mm Probe Single Kit); OptaBlate BVN Intraosseous Nerve Ablation…K250213 · Stryker Instruments · May 15, 2025
- RF CannulaK241367 · Shanghai Samedical & Plastic Instruments Co., Ltd. · Jan 23, 2025
- Intracept Intraosseous Nerve Ablation SystemK222281 · Relievant Medsystems, Inc. · Oct 26, 2022
- Intracept Intraosseous Nerve Ablation SystemK213836 · Relievant Medsystems, Inc. · Mar 11, 2022
- Document
- 510(k) summary (PDF) ↗
- Type
- Traditional
- Received
- Dec 22, 1999
- Review panel
- Neurology
- Regulation
- 21 CFR 882.4725
One page per 510(k), De Novo and original PMA. Recalls are those FDA's recall database ties to this number; recalls of related devices that cite another number are not shown. Refreshed weekly. Predicates are read by Arca from the text of FDA's 510(k) summary PDFs, most of them scans: a device number counts when the summary names it as a predicate or as the device it is substantially equivalent to. About 97% of those read were right on a sample we checked by hand; summaries from before 2000 often name predicates without a number, so older devices show fewer. Pivotal studies are read by a model from FDA's De Novo decision summaries and PMA SSEDs; a count or result is shown only when its numbers appear in FDA's text. openFDA device 510(k), PMA and recall files